D69-P06-01 GB R6
01/07/2020
www.photowatt.com
10
GROUNDING METHOD :
BOLT + TOOTHED NUT + CUP WASHER
•
A grounding kit containing an M5 (3/16") SS cap
bolt, an M5 (3/16") SS flat washer, an M5 (3/16")
SS cup washer, and an M5 (3/16") SS nut (with
teeth) is used to attach copper grounding wire
to a pre-drilled grounding hole on the frame
(see image below).
•
Place the wire between the flat washer and the
cup washer. Ensure that the cup washer is po-
sitioned between the frame and the wire with
the concave side up to prevent galvanic cor-
rosion. Tighten the bolt securely using the SS
toothed nut. A wrench may be used to do this.
The tightening torque is 3-7 Nm (2.2-5.2 ft-lbs).
6.0
MOUNTING INSTRUCTIONS
The applicable regulations pertaining
to work safety, accident prevention and
securing the construction site must be
observed. Workers and third party per-
sonnel shall wear or install fall arrest equipment.
Any third party need to be protected against inju-
ries and damages.
•
The mounting design must be certified by a re-
gistered professional engineer. The mounting
design and procedures must comply with all
applicable local codes and requirements from
all relevant authorities.
•
The module is considered to be in compliance
with UL 1703 and IEC 61215 only when the mo-
dule is mounted in the manner specified by the
mounting instructions included in this installa-
tion manual.
•
Any module without a frame (laminate) shall not
be considered to comply with the requirements
of UL 1703 unless the module is mounted with
hardware that has been tested and evaluated
with the module under this standard or by a field
inspection certifying that the installed module
complies with the requirements of UL 1703.
•
EDF ENR PWT does not provide mounting hard-
ware.
•
Standard modules can be mounted onto a sup-
port structure using one of several approved
methods. One of such methods is described be-
low. For details of other mounting methods and
the methods recommended by Canadian Solar
Inc. for special module ranges, please refer to
the Annex A (Alternative Mounting Methods) of
this installation manual. For information about
other installation methods, please contact your
local representative. Failure to use a recognized
installation method will void the EDF ENR PWT
warranty.
•
Use appropriate corrosion-proof fastening
materials. All mounting hardware (bolts, spring
washers, flat washers, nuts) should be hot dip
galvanized or stainless steel.
•
Use a torque wrench for installation.
•
Do not drill additional holes or modify the
module frame. Doing so will void the warranty.
•
Standard modules can be installed in either
landscape or portrait orientations. Refer to
the detailed instructions for further guidance.
Please note that in areas with heavy snowfall (>
2400 Pa) further countermeasures such the use
of additional support bars should be conside-
red to avoid snow loads damaging the lowest
row of modules.
•
In cases where an additional support bar is re-
commended to improve both mechanical sta-
bility and long-term module performance, we
recommend selecting a sufficiently resistant
material. EDF ENR PWT recommends bars with
a minimum thickness of 50 mm (1.97 in). The
support bar centerline should be positioned
within 100 mm (3.94 in) of the side frame cen-
terline (slight shifts may be necessary to access
module grounding holes).
•
The loads described in this manual correspond
to test loads. For installations complying with
IEC 61215-2: 2016 and UL 1703, a safety fac-
tor of 1.5 should be applied for calculating the
equivalent maximum authorized design loads.
Project design loads depend on construction,
applicable standards, location and local cli-
mate. Determination of the design loads is
1. To fix the wire between
the flat washer and cup wa-
sher, place the cup washer
(concave side up) between
the frame and the wire.
2. Then tighten the bolt
using the toothed nut
Summary of Contents for PW60HT-C-XF
Page 1: ...INSTALLATION MANUALS For professional use only...
Page 2: ...INSTALLATION MANUAL FOR STANDARD MODULES For professional use only...
Page 27: ...INSTALLATION MANUAL OF DOUBLE GLASS MODULES For professional use only...