D84-P06-01 GB R2
28/07/2020
www.photowatt.com
18
6.3
MOUNTING METHODS FOR FRAMED BIFACIAL
MODULE (SINGLE-AXIS TRACKER)
•
The bolts and clamps used in this section should
follow the requirements in 6.3 and 6.4.
•
Under any conditions the junction box cannot
become in contact with the subjacent racking
structure. If any racking structures, especially
bearing house, have to be located under the
modules, the gap between the junction box and
the racking structure should be at least 30 mm
(PW72HT, PW60HT) and 50 mm (PW72LHT).
•
If your tracker design cannot meet the above
distance requirement, please contact EDF ENR
PWT technical support department in writing
for advices.
PW72HT-CB-XF
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
Two modules share one tube, portrait installation.
Bolting on long frame side using 1155 mm moun-
ting holes.
Mounting rails run parallel to the long side frame.
Mounting rails fixed on torque tube (tracker).