FASTCAM-APX RS Hardware Manual
-152-
6.1.2. Miscellaneous Information
Operating Conditions
Ambient
temperature
0 to 40 degrees Celsius (32 to 104 degrees Fahrenheit), no condensation.
For temperature over 35 degrees Celsius, heat sink is required (optional)
Relative humidity
0 to 85 %, no condensation
Impact resistibility
100 G, 10 msec, 6 axes (exept for AC power adapter unit)
Mechanical Data
Camera body
158.6 (H)
×
131.4 (W)
×
280.6 (D) mm (6.3 x 5.2 x 11.1 inches)
(with C mount, except other protrusions)
AC power adapter
63.5 (H)
×
95 (W)
×
178 (D) mm (2.5 x 3.8 x 7.0 inches), except
protrusions
Remote keypad
105 (H)
×
140 (W)
×
20.8 (D) mm (4.2 x 5.5 x 0.9 inches), except
protrusions
Power Requirement
Voltage
100 to 120/200 to 240 VAC (automatic changeover)
Frequency
50 or 60 Hz
Power
consumption
Approx. 210 VA
DC Power
V12
VDC
Current
Approx. 6.3 A
Weight
Camera body
4.9 kg
AC power adapter
1 kg
Remote keypad