Manual I1AM02
MA 1296-A010 EN
38
8 Heating of the I1AM02 Module
i
The adjusting module temperature depends on the motor type, the motor
cable length, phase current, supply voltage and the tolerance of the
components.
In practice it can differ from the diagrams below.
Measuring conditions or operation:
Module vertical arranged
60 V
DC
supply voltage
Motortype: ZSH 87.200.6,5
Temperatures are normalised, i.e. relatively to the ambient temperature
The power stage temperature (measured on the board or heat sink) should not exceed
85 °C to prevent the destruction of the hardware. The power stage has an internal
emergency shutdown.
8.1 with APS Power Stage
Normalised power stage temperature, max. current (3.5 A
r.m.s
), 100% duty cycle
Fig.11 Heating curve of the APS power stage and output power
Summary of Contents for phyMOTIONT I1AM02.1
Page 9: ...phytron 9 MA 1296 A010 EN 4 Technical Data 4 1 Declaration of Incorporation...
Page 10: ...Manual I1AM02 MA 1296 A010 EN 10...
Page 30: ...Manual I1AM02 MA 1296 A010 EN 30 Fig 6 6 wire LVDT RVDT wiring...
Page 31: ...phytron 31 MA 1296 A010 EN Synchronisation Fig 7 Synchronisation wiring...