Now you can select the media to which the App should have 
access under "Denied". You then only have to allow access 
afterwards. 
 

5.3.6    Establishing a USB connection to a PC. 

If  you  want  to  transfer  data  such  as  pictures,  videos  or 
measured value files to a connected PC, you must first acti-
vate the USB connection and then release it for file transfer. 
 
Click  on  the          settings  icon  on  the  home  screen  and  then 
select       Display. 
 

 

 
Activate the "USB Device" switch here. 
Now establish the connection to the PC. To do this, use the 
USB-C socket (16.) on the SMARTlink. 
 
In  the  message  centre  (see  5.3.2)  you  will  now  see  the  in-
formation that the device is being charged via USB. Click on 
this message to change it. 
 

  
 
Now select "File Transfer" for "This device". 
 
On  the  PC,  the  unit  is  now  displayed  to  them  as 
"SMARTlink" and they can access the directories and files of 
the SMARTlink. 
 

If the SMARTlink is configured as a USB device, 
the  internal  sensors  cannot  be  accessed  in 
measureAPP.  Therefore,  terminate  the  USB 
connection after each data transfer. 

 
 

5.4 Use of internal and external sensors 

Cobra SMARTlink has 7 internal sensors for a variety of ex-
periments. 
 

 

 
 
 
 
 
 
 

5.4.1        Light    

1…128 kLx 

 
 

5.4.2         UV   0...400 W/m² 

 
  

5.4.3         Relative Humidity 0...100 % 

 
 

5.4.4         Thermocouple  -200...1200°C 

Connect the NiCrNi temperature sensors (type K) included in 
the scope of delivery here. Make sure  the polarity is correct 
(the negative pole is wider). See picture above. 
 

5.4.5          Voltage   ± 30V 

Measure  the  voltage  using  the  4mm  test  leads  included  in 
the  delivery.  The  exemplary  connection  of  a  voltage source 
with load is shown above. 
 

Do  not  measure  voltage  above  30V  or  below  -
30V.  This  can  lead  to  the  destruction  of  the 
measuring electronics. 

 

5.4.6.          Current   ±1A 

Measure  the  current  using  the  4mm  test  leads  included  in 
the  delivery.  The  exemplary  connection  of  a  voltage source 
with load is shown above. 
 

Do not measure currents above 1A or below -1A. 
Although  the  measuring  input  is  protected  by  a 
self-resetting fuse, very high currents (e.g. due to 
a short circuit) can destroy the unit.  

 

5.4.7 Using the USB ports (10.) 

Connect USB-capable Cobra SMARTsense sensors to USB 
ports  1-4.  In measureAPP,  you  still  have  to  allow  access  to 
the USB port for the app after plugging in the sensors. Once 
this  is  done,  you  can  connect  directly  to  the  sensors.  A 
SMARTsense  sensor  does  not  need  to  be  switched  on  to 
connect to the USB.  
 

5.4.8 Using Bluetooth sensors 

Using  Bluetooth-enabled  sensors  such  as  SMARTsense  or 
DigiCart  is  very  easy.  Just  switch  on  the  sensors  and  start 
measureAPP    when  using  SMARTsense  sensors  or        
DigiCartAPP  when  using  the  DigiCart.  In  measureAPP  the 
Cobra  SMARTsense  sensors  are  directly  available  and  can 
be  selected.  In  DigiCartAPP,  the  DigiCart  can  also  be  se-
lected and connected directly. 
 

Bluetooth sensors require "location sharing" both 
for the app and globally in the operating system. 
See chapter 5.3.4. 

 

Summary of Contents for Cobra SMARTlink

Page 1: ...ssary to avoid damage to it as well as for user safety Use the unit only for its intended purpose Protect the device from dust moisture and vapours Clean the unit with a slightly damp lint free cloth Sharp cleaning agents or solvents are unsuitable Make sure that no liquid enters the housing openings Do not open the device The voltage measurement input of the unit is intended for signals in the ra...

Page 2: ...led in current EC guidelines The characteristics of this product qualify it for the CE mark This device is only to be put into operation under specialist supervision in a controlled electromagnetic environment in research educational and training facilities schools univer sities institutes and laboratories The individual connected lines must not be longer than 2m Electrostatic charges or similar e...

Page 3: ...he Start button to pro ceed with the initial setup Select the appropriate Wi Fi network to which you want to connect the tablet If you click the Set up offline option some Google services cannot be set up If content is to be transferred from a previously used device the Next button must be pressed here otherwise please select Do not copy If you have a Google account you can now sign in to Google P...

Page 4: ... at a later time 5 2 3 Switch off the device Press the switch on button for longer than 3s Now you will see a selection window on the right hand side for switching off the unit or restarting the device If you press the power button only briefly you only switch off the display 5 3 Using Android The following section deals with the basic use and settings of Android Due to the large number of setting...

Page 5: ...he Apps This is necessary so that connected Cobra SMARTsense sensors or Cobra DigiCart can communicate via Bluetooth Low Energy Please confirm the release If location sharing is rejected neither Cobra SMARTsense sensors nor DigiCart can be de tected At measureAPP all connected sensors as well as the in ternal sensors are displayed on the left under Devices If you want to use the internal SMARTlink...

Page 6: ...e scope of delivery here Make sure the polarity is correct the negative pole is wider See picture above 5 4 5 Voltage 30V Measure the voltage using the 4mm test leads included in the delivery The exemplary connection of a voltage source with load is shown above Do not measure voltage above 30V or below 30V This can lead to the destruction of the measuring electronics 5 4 6 Current 1A Measure the c...

Page 7: ...WxH 277 x 175 x 25 mm Weight full scale 830 g 7 SCOPE OF DELIVERY The scope of delivery includes Cobra SMARTlink 12999 99 USB connection cable type C USB charging adapter 5V 2A 2x NiCrNi temperature sensor type K 2x connection cable red 4mm l 50cm 1x connection cable blue 4mm l 50cm Operating instructions 8 ACCESSORIES The following accessories are available USB connection cable type C07935 00 Sof...

Reviews: