10 Specifications
42
Version: 1.0.1
MP158D
L-731 / V-731 Precision XY Positioner
V-731.096111
Unit
Tolerance
Miscellaneous
Operating temperature range 10 … 50
°C
Humidity
20 … 90 % rel., not condensing
Material
Aluminum, black anodized
Motor connector
2 × HD D-Sub 26 (m)
Sensor connection
2 × D-Sub 15 (f)
Recommended controller
SMC Hydra
C-891
Modular ACS controller
10.1.2
Maximum Ratings
The L-731 / V-731 positioners are designed for the following operating data:
Model
Maximum operating
voltage
Operating frequency Maximum power
consumption*
L 731.093111
L 731.093112
L 731.093132
48 V
0 Hz
60 W
L-731.4xSD
48 V
0 Hz
5 W
V-731.096111
48 V
0 Hz
3 W
* per axis
10.1.3
Ambient Conditions and Classifications
The following ambient conditions and classifications must be observed for the L-731 / V-731:
Area of application
For indoor use only
Maximum altitude
2000 m
Relative humidity
20% … 90%, not condensing
Storage temperature
10 °C … 50 °C
Transport temperature
10 °C … 50 °C
Supply fluctuations
Max. ±10 % of the nominal voltage
Degree of pollution
2
Degree of protection according to IEC 60529
IP00