NOTICE
Impermissibly high load on the positioners!
In a multi-axis system, the stage used for the upper axis must also be moved. Impermissibly
high loads impair the motion and can damage the positioners.
►
Pay attention to the
maximum permissible forces (p. 32)
that may act on the motion
platform.
►
In the case of multi-axis systems, include the masses of the positioners to be moved
when calculating the load.
NOTICE
Excessively long screws and locating pins
Screws and locating pins that are inserted too deeply can damage the L-505.021212.
►
Pay attention to the
depth of the mounting and locating holes (p. 35)
in the L-505.021212.
►
Only use screws and locating pins of the correct length for the respective mounting holes.
NOTICE
Protruding screw heads!
Protruding screw heads can damage the L-505.021212.
►
Make sure that the screw heads are fully countersunk and cannot interfere with motion.
NOTICE
Damage due to mechanical stress on the cable!
The cable will break from excessive or repeated bending. A broken cable will lead to failure
of the L-505.021212 or damage to the L-505.021212 or the electronics.
►
Install the L-505.021212 so that the cable has a bending radius of
≥
35 mm.
►
If necessary: Use cables that are approved for recurring mechanical loading (e.g., drag
chain cables).
Building an XY Multi-Axis System
1. Mount the L-505.021212 onto the lower L-505.
a) Insert the two locating pins into the motion platform of the lower L-505.
2. Align the L-505.021212 to the lower L-505.
3. Insert the screws into the holes in the upper L-505 and tighten them.
6 INSTALLATION
L505M0015EN
‒
3/18/2020
17
M O T I O N | P O S I T I O N I N G