Z Mounting Overview
The adapter bracket for the L-505 can be attached in two different configurations.
Requirements
✓
You have read and understood the
general safety instructions (p. 8)
✓
The positioners are not connected to the electronics.
✓
The lower positioner has been
mounted onto the underlying surface properly (p. 14)
✓
You have accounted for the space required to route cables without bending and
according to regulations.
NOTICE
Impermissibly high load on the positioners!
In a multi-axis system, the stage used for the upper axis must also be moved. Impermissibly
high loads impair the motion and can damage the positioners.
►
Pay attention to the
maximum permissible forces (p. 32)
that may act on the motion
platform.
►
In the case of multi-axis systems, include the masses of the positioners to be moved
when calculating the load.
NOTICE
Excessively long screws and locating pins
Screws and locating pins that are inserted too deeply can damage the L-505.021212.
►
Pay attention to the
depth of the mounting and locating holes (p. 35)
in the L-505.021212.
►
Only use screws and locating pins of the correct length for the respective mounting holes.
NOTICE
Protruding screw heads!
Protruding screw heads can damage the L-505.021212.
►
Make sure that the screw heads are fully countersunk and cannot interfere with motion.
6 INSTALLATION
L505M0015EN
‒
3/18/2020
19
M O T I O N | P O S I T I O N I N G