2. Drive screw
Auxiliary Materials Required
■
Lubricant for the drive screw: Isoflex Topas 30
■
Lubricant for the guides: Klüberquiet BQ 72
‑
72
Relubricating
Under laboratory conditions, it is only necessary to relubricate the L-505.021212 in
exceptional cases. For continuous industrial use, the lubrication intervals must be defined
individually.
If you have any questions on relubricating, contact our
customer service department (p. 31)
.
8.3
Cleaning
Requirements
✓
You have disconnected the L-505.021212 from the electronics.
Auxiliary Materials Required
■
Soft, lint-free cloth
■
Mild cleaning agent or disinfectant
If you have any questions on the auxiliary materials recommended for the L-505.021212,
contact our
customer service department (p. 31)
NOTICE
Damage due to unsuitable cleaning agents!
Some cleaning agents can cause rusting on the L-505.021212 or dissolve plastics, paints or
adhesives.
►
Do not clean with water or acetone.
Cleaning the L-505.021212
1. Dampen the cloth with the cleaning agent or disinfectant.
2. Carefully wipe the surfaces of the L-505.021212.
8.4
Moving the Motion Platform by Hand
It may be necessary to move the motion platform manually,
■
to allow access to the mounting holes in the positioner's base body for the mounting
screws,
■
to move the motion platform away from the mechanical hard stop and make the
L-505.021212 operational again.
Requirements
✓
You have disconnected the L-505.021212 from the electronics.
Moving the Motion Platform by Hand
1. Remove the protective earth connector. See
Connecting the L-505.021212 to the Protective
.
8 MAINTENANCE
L505M0015EN
‒
3/18/2020
27
M O T I O N | P O S I T I O N I N G