Miscellaneous
Unit
Tole-
rance
L-505.023212
Operating temperature range
°C
5 to 40
Material
Anodized aluminum, stainless
steel
Mass
kg
±5 %
0.4
Moved mass
g
±5 %
0.07
Connector
HD D-sub 26 (m)
Cable length
m
±10 mm 0.5
Recommended controllers
C-863 (single axis)
C-884 (up to 6 axes)
C-885 with C-863.20C885 (up
to 40 axes)
ACS modular controller
12.2
Maximum Ratings
The L-505.023212 is designed for the following operating data:
Maximum operating voltage Maximum operating fre-
quency
Maximum power consump-
tion
48 V
‑
7 W
12.3
Ambient Conditions and Classifications
The following ambient conditions and classifications for the L-505.023212 must be observed:
Area of application
For indoor use only
Maximum altitude
2000 m above msl
Relative humidity
20 to 80%, not condensing
Storage temperature
-20 °C to +70 °C
Transport temperature
-20 °C to +70 °C
Supply voltage fluctuations
Max. ±10 % of the nominal voltage
Degree of pollution
2
Degree of protection according to IEC 60529 IP00
12 TECHNICAL DATA
L505M0017EN
‒
3/18/2020
34
M O T I O N | P O S I T I O N I N G