10 Technical Data
40
Version: 1.3.0
MP144E
N472 Linear Actuator
10.1.3
Maximum Ratings
N-472 linear actuators are designed for the following operating data:
Model
Maximum operating
voltage
Maximum operating
frequency during
continuous operation*
Maximum power
consumption
N-472.xx0
N-472.xx0Y
80 V
400 Hz
5 W
N-472.xxV
N-472.xxVY
80 V
200 Hz
5 W
* Up to 2000 Hz is permissible for short periods of time. See "Operating Time and Duty Cycle"
(p. 42).
10.1.4
Ambient Conditions and Classifications
The following ambient conditions and classifications for the N-472 must be observed:
Area of application
For indoor use only
Maximum altitude
2000 m
Air pressure
Models N-472.xx0 and N-472.xx0Y:
1100 hPa to 0.1 hPa
Models N-472.xxV and N-472.xxVY:
1100 hPa to 10
-6
hPa (high vacuum)
Relative humidity
Highest relative humidity 80 % for temperatures up to 31 °C
Decreasing linearly to 50 % relative humidity at 40 °C
Operating temperature
10 °C to 40 °C
Storage temperature
-20 °C to 75 °C
Transport temperature
-20 °C to 75 °C
Overvoltage category
II
Protection class
I
Degree of pollution
1
Degree of protection according to
IEC 60529