6 Starting and Operating
P611 Positioners
PZ253E
Version: 1.2.0
25
In this Chapter
General Notes on Starting ........................................................................................................... 25
Operating the P-611 ..................................................................................................................... 26
Discharging the P-611 .................................................................................................................. 27
6.1
General Notes on Starting
CAUTION
Risk of electric shock if the protective earth conductor is not connected!
If a protective earth conductor is not or not properly connected, dangerous touch voltages can
occur on the P-611 in the case of malfunction or failure of the system. If there are touch
voltages, touching the P-611 can result in minor injuries from electric shock.
Connect the P-611 to a protective earth conductor (p. 18) before starting.
Do
not
remove the protective earth conductor during operation.
If the protective earth conductor has to be removed temporarily (e.g., in the case of
modifications), reconnect the P-611 to the protective earth conductor before restarting.
NOTICE
Destruction of the piezo actuator due to electric flashovers!
Using the P-611 in environments that increase the electrical conductivity can lead to the
destruction of the piezo actuator by electric flashovers. Electric flashovers can be caused by
moisture, high humidity, liquids, and conductive materials (e.g., metal dust). In addition,
electric flashovers can also occur in certain air pressure ranges due to the increased
conductivity of the air.
Avoid operating the P-611 in environments that can increase the electric conductivity.
Operate the P-611 only within the permissible ambient conditions and classifications
(p. 41).
NOTICE
Decreased lifetime due to permanently high voltage!
Applying a continuous high static voltage to piezo actuators reduces the lifetime of the piezo
ceramic.
When the P-611 is not used but the electronics remain switched on to ensure temperature
stability, discharge the P-611 (p. 27).
6
Starting and Operating
Summary of Contents for P-611 Series
Page 8: ......
Page 12: ......
Page 20: ......
Page 32: ......
Page 34: ......
Page 38: ......
Page 47: ...10 Technical Data P 611 Positioners PZ253E Version 1 2 0 43 Figure 11 P 611 10 ...
Page 48: ...10 Technical Data 44 Version 1 2 0 PZ253E P 611 Positioners Figure 12 P 611 2S and P 611 20 ...
Page 49: ...10 Technical Data P 611 Positioners PZ253E Version 1 2 0 45 Figure 13 P 611 XZS and P 611 XZ0 ...
Page 51: ...10 Technical Data P 611 Positioners PZ253E Version 1 2 0 47 Figure 15 P 611 ZS ...
Page 52: ...10 Technical Data 48 Version 1 2 0 PZ253E P 611 Positioners Figure 16 P 611 Z0 ...
Page 56: ......
Page 58: ......