P725T0010, valid for P-725 

 

 

 

Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstr. 1, 76228 Karlsruhe/Germany 

Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, 

www.pi.ws

 

About this Document 

Symbols and Typographic Conventions 

The following symbols and typographic conventions are used in this user manual: 

 

CAUTION 

 

Dangerous situation 

If not avoided, the dangerous situation will result in minor injury. 

  Actions to take to avoid the situation. 

  

 

NOTICE 

 

Dangerous situation 

If not avoided, the dangerous situation will result in damage to the equipment. 

  Actions to take to avoid the situation. 

  

 

INFORMATION 

 

Information for easier handling, tricks, tips, etc. 

 

Figures 

For better understandability, the colors, proportions, and degree of detail in illustrations can deviate 
from the actual circumstances. Photographic illustrations may also differ and must not be seen as 
guaranteed properties. 
 

Safety 

Intended Use 

The P-725 is a laboratory device as defined by DIN EN 61010-1. It is intended to be used in interior 
spaces and in an environment which is free of dirt, oil and lubricants. 
 
Based on its design and realization, the P-725 is intended for positioning and shifting microscope 
objectives in one axis. 
 
The P-725 Z drive can be mounted horizontally or vertically. The specifications refer to a vertically 
mounted Z drive. 
 
The intended use of the P-725 is only possible in a completely assembled and connected state. The 
P-725 must be operated with a suitable controller that is available from PI. The controller is not 
included in the scope of delivery of the P-725. 
 

Summary of Contents for PIFOC P-725 series

Page 1: ...lid for P 725 Physik Instrumente PI GmbH Co KG Auf der Roemerstr 1 76228 Karlsruhe Germany Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi ws www pi ws P 725 PIFOC Long Travel Objective Scanner...

Page 2: ...ing the P 725 to the Protective Earth Conductor 9 Affixing the P 725 to the Microscope 10 Installing the Objective 12 Startup and Operation 13 General Notes on Startup and Operation 13 Starting Up and...

Page 3: ...r understandability the colors proportions and degree of detail in illustrations can deviate from the actual circumstances Photographic illustrations may also differ and must not be seen as guaranteed...

Page 4: ...ock max 120 V DC and minor injuries Do not touch the contacts in the connector Secure the connector of the piezo actuator with screws against being pulled out of the controller CAUTION Risk of electri...

Page 5: ...adapters P 725 1CL PIFOC piezo nanofocusing Z drive for long scanning ranges 100 m capacitive sensors LEMO connectors for QuickLock thread adapters P 725 10L PIFOC piezo nanofocusing Z drive for long...

Page 6: ...400 m capacitive sensors LEMO connectors for QuickLock thread adapters P 725 40L PIFOC piezo nanofocusing Z drive for long scanning ranges 460 m open loop LEMO connectors for QuickLock thread adapters...

Page 7: ...nsecutive numbers PIFOC Brand name Country of origin Germany Country of origin Warning sign Observe manual Old equipment disposal p 25 WWW PI WS Manufacturer s address website CE conformity mark Manuf...

Page 8: ...hread adapter M32 x 0 75 mm 21 mm P 721 06Q QuickLock thread adapter M26 x 1 36 21 mm P 721 08Q QuickLock thread adapter M19 x 0 75 mm 14 mm P 721 11Q QuickLock thread adapter M25 x 0 75 mm 21 mm P 72...

Page 9: ...rvo controller amplifier E 625 servo controller bench top E 665 display servo controller with digital interface bench top E 709 single channel digital controller No sensor LEMO connection P 725 x0L E...

Page 10: ...onnection of the P 725 as shown in the profile view 3 Tighten the M4 screw with a torque of 1 2 Nm to 1 5 Nm 4 Make sure that the contact resistance at all connection points relevant for mounting the...

Page 11: ...ions p 3 Tools and accessories P721T0002 technical note for PIFOC QuickLock thread option p 7 QuickLock thread adapter p 8 not included Note that you only need the objective insert of the QuickLock th...

Page 12: ...e Z drive high torques and the danger of oscillations Figure 5 Center of load far below the aperture Requirements You have read and understood the safety precautions p 3 You have affixed the P 725 to...

Page 13: ...y of the air Avoid operating the P 725 in environments that can increase the electric conductivity Only operate the P 725 within the permissible ambient conditions and classifications p 25 NOTICE Dest...

Page 14: ...be replaced recalibrate the axis displacement see controller manual or contact our customer service department p 15 Starting Up and Operating the P 725 Requirements You have read and understood the sa...

Page 15: ...an the surface of the P 725 with a cloth that is lightly dampened with a mild cleanser or disinfectant e g ethanol or isopropyl alcohol Do not do any ultrasonic cleaning Customer Service For inquiries...

Page 16: ...pacitive Capacitive Open loop travel 20 to 120V 150 330 460 as P 725 xCL m min 20 0 Closed loop travel 100 250 400 m calibrated Open loop resolution 0 3 0 4 0 5 as P 725 xCL nm typ Closed loop resolut...

Page 17: ...pe PICMA P 885 PICMA P 885 PICMA P 885 as P 725 xCL Electrical capacitance 4 2 6 2 6 2 as P 725 xCL F 20 Dynamic operating current coefficient 5 2 3 1 1 9 as P 725 xCL A Hz m 20 Miscellaneous Operatin...

Page 18: ...lity 1 5 5 nm typ Runout X Y 2 2 rad typ Crosstalk in X Y 150 150 nm typ Mechanical properties Stiffness in motion direction 1 5 1 5 N m 20 Resonant frequency no load 1180 1180 Hz 20 Resonant frequenc...

Page 19: ...76228 Karlsruhe Germany Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi ws www pi ws Dimensions Dimensions in mm Note that the decimal places are separated by a comma in the drawings P 725 xCD...

Page 20: ...valid for P 725 Physik Instrumente PI GmbH Co KG Auf der Roemerstr 1 76228 Karlsruhe Germany Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi ws www pi ws P 725 xCA Figure 7 P 725 xCA P 721 xxA...

Page 21: ...2018 11 13 P725T0010 valid for P 725 Physik Instrumente PI GmbH Co KG Auf der Roemerstr 1 76228 Karlsruhe Germany Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi ws www pi ws P 725 xDD Figure 8...

Page 22: ...L bottom 1 LEMO coaxial connector for capacitive sensor Probe 2 LEMO coaxial connector for capacitive sensor Target 3 LEMO coaxial connector for piezo voltage LEMO coaxial connectors Figure 10 LEMO co...

Page 23: ...ws www pi ws P 725 SDD Figure 11 LEMO connectors of P 725 SDD 1 4 pin LEMO connector for strain gauge sensor 2 LEMO coaxial connector for piezo voltage Sensor connector Figure 12 Sensor connector fron...

Page 24: ...sensor A2 outer conductor GND Shield 1 Bidirectional Data line for ID chip 2 GND Shield of Target Ground of ID chip when switched on 3 Input Piezo voltage 4 N C Not connected 5 Input Target sensor si...

Page 25: ...temperature 25 C to 85 C Overvoltage category II Protection class I Degree of pollution 1 Degree of protection according to IEC 60529 IP20 Old Equipment Disposal In accordance with EU law electrical...