Miscellaneous
V-412
Unit
Toler-
ance
Operating Temperature
Range
5 to 40
°C
Material
Aluminum, black anodized
stainless steel
Overall mass
V-412.03 (52 mm travel range): 5.0
V-412.05 (102 mm travel range): 5.6
V-412.09 (204 mm travel range): 6.7
V-412.13 (305 mm travel range): 7.9
V-412.17 (407 mm travel range): 9.0
V-412.21 (508 mm travel range): 10.2
V-412.25 (610 mm travel range): 11.3
kg
±5 %
Moved mass
1.7
kg
±5 %
MTBF
20000
h
Connector
M15 (motor)
M15 (linear encoder)
Fitting for purge air hose with outside diame-
ter 4 mm
Purge air system
Operating pressure: 2 to 6 bar (200 to 600
kPa)
Relative humidity: < 70 %
Absolute humidity: < 35 g/m
3
Recommended controllers
ACS modular controller
12.2
Maximum Ratings
The V-412.xx6025E0 is designed for the following operating data:
Maximum operating voltage Maximum operating fre-
quency
Maximum peak current, RMS
300 V
–
10.6 A
12.3
Ambient Conditions and Classifications
The following ambient conditions and classifications for the V-412.xx6025E0 must be
observed:
12 TECHNICAL DATA
V412M0008EN
‒
5/11/2020
30
M O T I O N | P O S I T I O N I N G