4. Make sure that the contact resistance is <0.1
Ω
at 25 A at all connection points relevant for
attaching the protective earth conductor.
6.3
Building a Multi-Axis System
The V-417.xx6025E0 can be used in XY systems.
Designations in these instructions:
■
Lower positioner: Forms the basis of the multi-axis system, is attached to an underlying
surface
■
Upper positioner: Forms the upper axis of the multi-axis system, is attached to the lower
positioner rotated by 90°
NOTICE
Excessively long screws and locating pins
Screws and locating pins that are inserted too deeply can damage the V-417.xx6025E0.
►
Pay attention to the
depth of the mounting and locating holes (p. 29)
V-417.xx6025E0.
►
Only use screws and locating pins of the correct length for the respective mounting holes.
6.4
Mounting the Load onto the V-417.xx6025E0
Overview
1
1
1
1
2
3
Figure 7: Mounting the load onto the V-417.xx6025E0
1. Screws
2. Load
3. Motion platform of the V-417.xx6025E0
Tools and Accessories
■
At least 3 screws with suitable
■
Suitable tool for tightening the screws
■
Optional: 2 suitably dimensioned dowel pins as locating pins for aligning the load on the
V-417.xx6025E0
6 INSTALLATION
V417M0010EN
‒
4/26/2019
16
M O T I O N | P O S I T I O N I N G