NOTICE
Operating voltage excessively high or incorrectly connected!
Operating voltages that are too high or incorrectly connected can cause damage to the
V-417.xx6211E0.
►
Pay attention to the
operating voltage range (p. 27)
, which is specified for the
V-417.xx6211E0.
►
Pay attention to correct
NOTICE
Damage due to collisions!
Collisions can damage the V-417.xx6211E0, the load to be moved, and the surroundings.
►
Stop the motion immediately if an electronics malfunction occurs.
►
If possible, adapt the travel range limits of your mechanical system in the software that
you use for commanding the motion.
NOTICE
Uncontrolled oscillation!
Oscillation can cause irreparable damage to the V-417.xx6211E0. Oscillation is indicated by a
humming noise and can result from the following causes:
■
The load and/or dynamics during operation differ considerably to the calibration settings.
■
The V-417.xx6211E0 is operated near to its resonant frequency.
►
If you notice oscillation, stop the V-417.xx6211E0 immediately.
Starting and Operating the V-417.xx6211E0
1. Start the electronics (see the user manual for the electronics).
2. Configure the electronics for the V-417.xx6211E0 during startup:
■
If you are using a digital controller from PI: In the PC software, select the entry in the
positioner database that matches the V-417.xx6211E0 exactly.
■
If you are using electronics from another manufacturer: Configure the electronics
according to the parameters of the V-417.xx6211E0.
3. Start a few motion cycles for testing purposes (see the user manual for the electronics).
7 STARTUP / OPERATION
V417M0009EN
‒
4/26/2019
20
M O T I O N | P O S I T I O N I N G