Miscellaneous
V-417
Unit
Toler-
ance
Operating Temperature
Range
5 to 40
°C
Material
Aluminum, black anodized
stainless steel
Overall mass
V-417.05 (102 mm travel range): 9.3
V-417.09 (204 mm travel range): 11.2
V-417.13 (305 mm travel range): 13.0
V-417.17 (407 mm travel range): 14.8
V-417.21 (508 mm travel range): 16.6
V-417.25 (610 mm travel range): 18.4
V-417.33 (813 mm travel range): 21.1
kg
±5 %
Moved mass
2.8
kg
±5 %
MTBF
20000
h
Connector
M17 (motor)
M17 (linear encoder)
Fitting for purge air hose with outside diame-
ter 4 mm
Purge air system
Operating pressure: 2 to 6 bar (200 to 600
kPa)
Relative humidity: < 70 %
Absolute humidity: < 35 g/m
3
Recommended controllers
ACS modular controller
12.2
Maximum Ratings
The V-417.xx6211E0 is designed for the following operating data:
Maximum operating voltage Maximum operating fre-
quency
Maximum peak current, RMS
300 V
–
15 A
12.3
Ambient Conditions and Classifications
The following ambient conditions and classifications for the V-417.xx6211E0 must be
observed:
12 TECHNICAL DATA
V417M0009EN
‒
4/26/2019
27