5 Installation
Q-522 Miniature Stage
MP134E
Version: 1.0.1
21
NOTICE
Damage from unsuitable cables!
Unsuitable cables can damage the electronics.
Only use cables provided by PI for connecting the Q-522 to the electronics.
INFORMATION
For the reproducibility of the positioning to be optimal, all components must be
affixed with zero-backlash.
Make sure that stage and load are affixed with zero-backlash.
INFORMATION
When handling the vacuum version of the stage, appropriate cleanliness must be
ensured.
Only touch the stage with powder-free gloves.
If necessary, wipe the stage clean.
INFORMATION
The positive direction of motion of the axis is given in the product view (p. 10).
5.2 Mounting the Q-522 on a Surface and Connecting It to
a Protective Earth Conductor
NOTICE
Protruding screw heads!
Protruding screw heads can damage the Q-522.
Ensure that the screw heads do not protrude from counter-sunk holes so that
they do not interfere with the stage motion.