The following table lists the settings for the parameters of the E-870 drive electronics.
Further information on the parameter settings is found in the "Operating Time" section
(p. 50).
Parameter
Parameter in E-870 Drive Electronics
Value
Unit
Operating voltage,
upper limit
PIShift Upper Supply Voltage
ID 0x1F000000
48
V
Operating voltage,
lower limit
PIShift Lower Supply Voltage
ID 0x1F000100
0
V
Charging current
during forward
motion
PIShift Forward Current
ID 0x1F000200
0.2
A
Charging current
during backward
motion
PIShift Backward Current
ID 0x1F000300
-0.2
A
Operating frequency
in step mode
PIShift Frequency
ID 0x1F000400
20000
Hz
Duty cycle of the
current source during
the output of one
period of the
modified sawtooth
signal in step mode
PIShift Charge Cycle
ID 0x1F000500
1
-
Number of steps the
stage moves per
second at the set
operating frequency.
PIShift Steps per Second
ID 0x1F000600
20000