5 Installation
16
Version: 1.0.0
MP124E
V-273 VC Linear Actuator
INFORMATION
For the positive direction of motion of the rod (X axis), see "Product Details" (p. 8) or
the dimensional drawing in "Dimensions" (p. 37).
5.2 Optional: Changing the Contact Piece of the Force
Sensor on the V-273.431 Model
INFORMATION
The mechanical coupling of the moving rod to a surface is achieved using the
contact piece of the force sensor. A contact piece made of aluminum and plastic is
installed by default.
If you change the contact piece, you may have to adapt the parameter settings
of the C-413 controller to the changed contact stiffness.
Prerequisites
The linear actuator is
not
connected to the controller.
Tools and accessories
Suitable contact piece with M3 internal thread
Changing the contact piece of the force sensor on the V-273.431
model:
1. Manually unscrew the contact piece to be replaced from the force sensor of
the V-273.431.
2. Manually screw the new contact piece onto the M3 threaded bolt of the force
sensor.
Maximum torque: 15 Ncm.