5 Installation
V-273 VC Linear Actuator
MP124E
Version: 1.0.0
19
Prerequisites
You have read and understood the general notes on installation (p. 15).
You have designed the mechanical mounting in which the V-273 is installed
as follows:
−
No
lateral forces are applied to the moving rod.
−
No
torque is applied to the moving rod.
−
Collisions are not possible.
When a V-273.431 is used, the mechanical mounting additionally meets the
following conditions:
−
When the controller is switched on or rebooted,
no
force is applied to the
contact piece of the connected force sensors.
−
The contact piece of the force sensor (see figure) is orthogonally oriented
to the counterforce that is applied to the moving rod.
You have provided a suitable surface on the fixed part of the mechanical
mounting for attaching the case of the V-273:
−
At least three M4 mounting holes are present. For the required position of
the holes, see "Dimensions" (p. 37).
−
The thickness of the surface, the depth of the holes and counterbores as
well as the length of the used screws are matched so that the maximum
screw-in depth in the V-273 is observed (p. 37).
−
The evenness of the surface is ≤20 µm.
−
For applications with great temperature changes:
The surface has the same thermal expansion properties as the V-273.
You have accounted for the space required for a cable routing free of kinks
and in accordance with regulations.
The linear actuator is
not
connected to the controller.
Tools and accessories
If the movable part of the mechanical mounting is to be connected to the
moving rod of the V-273.430: 1 to 2 M2 screws of suitable length (see
"Dimensions" (p. 37))
3 to 5 M4 screws of suitable length (see "Dimensions" (p. 37)) for attaching
the case of the V-273 to a surface