6 Start-Up and Operation
V-273 VC Linear Actuator
MP124E
Version: 1.0.0
23
NOTICE
Damage due to high velocity and moving to the hard stop with maximum force!
High velocities and moving to the hard stop with maximum force can cause damage,
strong heat development or considerable wear on the mechanical system.
Stop the motion immediately if a controller malfunction occurs.
Ensure that the end of the travel range is approached at low velocity and with
low force.
Set the control signal so that the moving part does not stop abruptly or try to
continue moving at the end of the travel range.
Determine the maximum velocity for your application.
NOTICE
Damage to the V-273 and the load from oscillations
The optimum values of the servo-control parameters of the controller depend on the
application and the moved mass. Unsuitable servo-control parameter settings of the
controller can cause the V-273 to oscillate. Oscillations can damage the V-273
and/or the load affixed to it.
If the V-273 is oscillating (unusual operating noise), immediately switch off the
servo mode for the axis on the controller or switch off the controller.
Only switch on the servo mode for the axis on the controller after you have
modified the servo-control parameter settings; see the manual of the controller.
NOTICE
Damage from transport lock that has not been removed!
Damage can occur to the linear actuator if the transport lock (p. 13) of the linear
actuator has not been removed and a motion is commanded.
Remove the transport lock before you start up the system consisting of the linear
actuator and the controller.
INFORMATION
The C-413 controller and the V-273 are delivered as a preconfigured system.
If a connection assignment is given on the labels of the controller and/or V-273,
observe this assignment when connecting the V-273.