Page 25 of 30
11.
TECHNICAL DATA
a.
Air consumption
Type
Air consumption at 0.5 MPa (NI/s)
KCS.XXXX.SX421.XX.XXX.XXXXXX.XX
2.21 (1 cartridge inside)
KCS.XXXX.SX422.XX.XXX.XXXXXX.XX
4.42 (2 cartridges inside)
Type
Air consumption at 0.5 MPa (NI/s)
KCS.XXXX.SX121.XX.XXX.XXXXXX.XX
0.72 (1 cartridge inside)
KCS.XXXX.SX122.XX.XXX.XXXXXX.XX
1.44 (2 cartridges inside)
b.
Pneumatic technical documentation
Descriprtion
Unit
SX42-ejector with (1-2 cartridge)
Feed pressure, optimal
MPa
0.5
Max vacuum at opt. pressure
-kPa
90
Air consumption at opt. pressure / cartridge
Nl/s
2.21
Max vacuum flow at opt. pressure/ cartridge
Nl/s
3.46
Descriprtion
Unit
SX12-ejector with (1-2 cartridge)
Feed pressure, optimal
MPa
0.5
Max vacuum at opt. pressure
-kPa
85
Air consumption at opt. pressure / cartridge
Nl/s
0.72
Max vacuum flow at opt. pressure/ cartridge
Nl/s
1.22
c.
Air specifications
Descriprtion
Supply air connection size
4mm internal diameter of hose by up to 2 meters (6.5ft)
Air quality
DIN ISO 8573-1 class 4
d.
Temperature specifications
Descriprtion
Operating temperature environment
0-50° (32-122F)
Operating temperature workpiece
0-50° (32-122F)