DT2012636-00
7.13 PROGRAMMING MAINTENANCE
a
Scheduled maintenance must be carried out ONCE A YEAR and prior to starting up the appliance, especially after a long period of
inactivity. This maintenance is necessary to ensure the appliance remains in efficient and safe working order.
a
The appliance must be DISCONNECTED FROM THE POWER SUPPLY for all cleaning and maintenance work.
a
Since the following maintenance necessitates removing some parts of the appliance, it is advisable to have the scheduled maintenance
carried out by an After-Sales Service Centre or a qualified person.
- Clean the grate (see “
CLEANING THE GRATE
”).
- Clean the firebox (see “
CLEANING THE FIREBOX
”).
- Clean the flue system (see “
CLEANING THE FLUE SYSTEM
”).
- Clean the painted metal parts (see “
CLEANING THE PAINTED METAL PARTS
”).
- Clean the glass (see “
CLEANING THE GLASS
”).
- Clean the fans (see “
CLEANING THE FANS
”).
- Clean away dust and cobwebs from the gap between the appliance and the cladding.
- Check the electrical part and the electronic components.
- Check the tightness and state of the gaskets/seals of the glass door and of all the elements subject to wear and if necessary replace.
- Carry out all maintenance and checks required for correct operation and compliance with safety regulations and standards.
- Light the appliance in accordance with instructions given under “
LIGHTING FOR THE FIRST TIME
”.
H07029330 / DT2001081 – 02