OPERATING AND INSTALLATION MANUAL SURFACE-MOUNTED UNIT LG 100 AP
PAGE 19
Changes reserved
12. Filter service
When the filter service life has elapsed (factory setting 6 months) the control unit
reports the necessity of a filter check. This takes place via the LED provided for this
purpose (on the bottom left), which will then be lit yellow permanently.
Required filter change
Reset the filter counter after changing the filter.
Press the [+] and the [-] button at the same time for 5 seconds in order to do this.
The filter message disappears after entering this combination.
Premature filter change
If the air filters are replaced prematurely, the filter counter must be reset without
a pending filter message.
To do this, you again press the [+] and the [-] button simultaneously for five sec-
onds.
When the filter service life has elapsed, the APP shows a filter mes-
sage via PUSH notification.
12.1. MINI control unit filter message
12.1.1. Clearing the MINI control unit filter message
12.3. Filter message via PICHLER APP
B
At every filter maintenance always all 3 filters must be replaced.
MINI control unit filter message
Flashing LED
12.4. Filter change
B
Only original replacement filters of the specified quality class
may be used.
B
When replacing the air filters, avoid soiling the unit and its components. Dirty air filters must be immediately and
suitably disposed of. The used air filters can be disposed of as residual waste.
When the filter service life has elapsed (factory setting 6 months), the unit
indicates a filter change on the control by the LED alternately flashing in
green and red. To acknowledge the filter message, press the button for
5
seconds
.
12.2. Filter message on the unit
GENERAL
USER
SPECIALIS