background image

OPERATING AND INSTALLATION MANUAL SURFACE-MOUNTED UNIT LG 100 AP 

 

 

 

 

 

 

             PAGE 9

Changes reserved

5.2. Safety regulations

Installation, initial start-up, maintenance and repairs must only be carried out by an authorised specialist company. 
 
Over and above this operating and installation manual, local and national regulations and standards shall also apply to the operation 
of this unit without limitation. 
 
Take instruction from your installer on the unit and on its control unit following installation. The ventilation unit may only be used in 
accordance with the information provided in Section 4 "Designated use”.  
 
All safety and danger notices attached to the unit and specified in this description must be observed.  
 
In the event of malfunctioning, switch off the unit immediately and disconnect all poles to switch the unit to zero potential. The unit 
must be appropriately secured against restart. Faults must be remedied immediately. 
 
After repairs and maintenance work, qualified personnel must verify that the unit is safe to operate.  
 
Attachment or installation of additional parts and components is not permitted. Any modification of the compact ventilation unit is 
prohibited. Only original spare parts may be used.  
 
Modifications and alterations to the ventilation unit are prohibited and absolve the manufacturer from all warranties and liability.  
 
Ensure that children do not play with the unit.

B

Attention/Note!

5. Safety

Read this operating and installation manual carefully and observe the safety instructions while you carry out installation, 
 commissioning, servicing or general work on the ventilation unit. Keep the operating and installation manual near the unit for its 
entire service life.  
 
Always observe the safety regulations, warnings and instructions given in this operating manual. 
The specifications given in this document must not be altered. Non-observance of these safety regulations, warnings and instructions 
may lead to physical injury or damage to the compact ventilation unit.  
 
The conclusion of a service contract is recommended to ensure that the unit will be checked at regular intervals. Ask your supplier 
about approved specialised companies/installers in your area.

The following Safety symbols highlight text containing warnings in respect of danger and potential hazards.
Please familiarise yourself with these symbols.

5.1. Symbols used in this document

B

Attention – High voltage! Ignoring this warning may lead to injury or threat to life and limb.

B

Attention! Ignoring this warning may lead to injury or threat to life and limb and/or damage to the unit.

GENERAL

USER

SPECIALIS

T PERSONNEL

Summary of Contents for 08LG100APF

Page 1: ...Systematic ventilation COMFORT VENTILATION OPERATING AND INSTALLATION MANUAL SURFACE MOUNTED UNIT LG 100 AP ...

Page 2: ...RATION PAGE 10 6 Customer service Page 11 7 Design of the ventilation unit Page 11 8 How to operate the unit Page 12 9 MINI control unit Page 13 9 1 FUNCTIONS PAGE 13 9 2 BUTTONS AND LEDS PAGE 13 10 Operation via PICHLER APP and PICHLER Connect Page 15 10 1 EASY OPERATION WITH THE PICHLER APP PAGE 15 10 2 REMOTE ACCESS WITH PICHLER CONNECT PAGE 15 10 3 DATA PROTECTION PAGE 15 10 4 CREATING AN ACCO...

Page 3: ...6 2 1 MOUNTING THE OUTDOOR AIR AND EXHAUST AIR CONNECTIONS PAGE 31 16 2 2 ASSEMBLY OF THE SURFACE MOUNTED HOUSING PAGE 32 16 2 3 INSERTING THE SLIDE IN MODULE INTO THE SURFACE MOUNTED HOUSING PAGE 33 16 3 ELECTRICAL CONNECTION PAGE 33 16 4 EXTERIOR WORK PAGE 36 16 4 1 DESIGN OF THE WEATHER PROTECTION GRILLE PAGE 36 16 4 1 1 ASSEMBLY FROM THE OUTSIDE PAGE 36 16 4 1 2 ASSEMBLY FROM THE INSIDE PAGE 3...

Page 4: ... Gesellschaft m b H AUSTRIA 9021 KLAGENFURT Karlweg 5 T 43 0 463 32769 www pichlerluft at Equipment type 08LG100DEFV Year of manufacture Volume flow max 80 m3 h Weight approx 35 kg Dimensions WxHxD 599x945x203 mm Voltage frequency 230V 50 Hz Power consumption max 320 W Order number Serial number J Pichler Gesellschaft m b H AUSTRIA 9021 KLAGENFURT Karlweg 5 T 43 0 463 32769 www pichlerluft at Equi...

Page 5: ...ounted design comprises a surface mounted housing 3 and a ventilation unit as slide in module 2 The ventilation unit is closed with a design front 1 at its front side The outdoor air and exhaust air connections are led to the outside via PVC pipe 4 and closed with the weather protection grille 5 GENERAL USER SPECIALIST PERSONNEL 1 2 Components of a surface mounted unit 3 4 5 ...

Page 6: ...nit Surface mounted unit with pre heating battery 08LG100APF 08LG100APFV Design front 08LG100UPAPDF1A Plastic pipe DN125 1m 08R1251000 Drilling template 30KARTONLG10012A Components for the façade finish Plastic grille NW155 for pipe diameter 80 125 mm 10TU125B Plastic grille NW170 foldable mountable from the inside for pipe diameters 100 140 mm 10DF140B USER GENERAL SPECIALIST PERSONNEL ...

Page 7: ...d user must also be instructed on potential hazards 4 Designated use 4 1 Intended use The compact ventilation unit LG 100 is intended for the installation into ventilation and air conditioning systems for controlled domestic ventilation in small and medium sized residential units approx 80 m The purpose of controlled mechanical ventilation and deaeration of domestic areas is to improve air quality...

Page 8: ...e over the roof The supply air must be provided for separately e g by window ventilation If an extractor hood without the separate provision of supply air is operated the balance of the air volume in the dwelling is no longer kept and the proper function of the dwelling s ventilation system is no longer ensured odour diversion etc Another option is to operate the extractor hood in recirculation mo...

Page 9: ... used Modifications and alterations to the ventilation unit are prohibited and absolve the manufacturer from all warranties and liability Ensure that children do not play with the unit B Attention Note 5 Safety Read this operating and installation manual carefully and observe the safety instructions while you carry out installation commissioning servicing or general work on the ventilation unit Ke...

Page 10: ...ly or identification of defects e g loose connections or burnt cables the unit must be switched off immediately Damaged or faulty power supply cables to the unit must be repaired immediately to avoid hazards The unit may not be operated until safe operational conditions are restored Fault finding and immediate remediation of electrical defects and malfunctions shall be carried out by authorised el...

Page 11: ...iately Ensure that you are safety conscious and aware of risks when you open the unit and when you remove cover plates Any work practices that could potentially impair the safety of the unit are prohibited The compact ventilation unit may be operated only in accordance with the project documentation which shall comply with the Equipment and Product Safety Act and the pertinent provisions of the EC...

Page 12: ...s an error or a warning message of the unit A detailed description of the error codes can be found in Section 19 2 LED and operating button on the bottom side of the unit LED Operating button Detailed view Pattern Description Flashing red 1 5 times Switch the unit to a deenergised state by switching it off and on If the error message remains active please contact the customer service Flashing red ...

Page 13: ...e The outdoor air and exhaust air flap opens and the fans convey the selected operating volume flow of ventilation level 1 With every further push of the button the ventilation unit is switched to the next higher ventilation level When the Automatic ventilation level LED flashing green 4 times has been reached the ventilation unit switches back to the Standby mode and switching starts again from t...

Page 14: ...active The LED of the current ventilation level is lit and the LED of ventilation level 3 flashes 9 Ventilation level LEDs Indicate the current ventilation level When all three LEDs are active this corresponds to the auto matic mode The ventilation unit follows a demand controlled air volume flow regulation via VOC When the defined time configurable has elapsed in the highest ventilation level ven...

Page 15: ...he illustration on the left the Access Point mode of the ventilation unit is activated and indicated by a green flashing of the WIFI LED As an alternative the Access Point mode is also activated if the control button on the unit is pressed for 10 seconds The mode is indicated by an LED that is flashing green permanently 10 1 Easy operation with the PICHLER APP Operational safety Remote access allo...

Page 16: ...s visible via the WLAN settings of the smartphone Select the network of the name LG100AHU and enter the password Pichler1234 When you have successfully established a connection with the ventilation unit open the PICHLER APP The following screen is shown Press the LG100 Access Point button in order to establish a direct connection with the ventilation unit Press the Login button The APP checks the ...

Page 17: ...e Internet router you must enter the network name WIFI SSID the WIFI password and the WIFI encryption Then press Accept The direct connection between the ventilation unit and your smartphone is interrupted If the Internet connection with the ventilation unit and your smartphone has been established successfully you must allocate an account name email address and a password Press the Save button an...

Page 18: ...n greater detail in Section 19 Error description Specialized personnel section In any case check the Internet connection and switch the unit on and off before consulting an expert 11 2 MINI control unit B The error messages of the compact ventilation unit on the MINI control unit are indicated by red error LED flashing patterns B The error messages of the compact ventilation unit are indicated in ...

Page 19: ...ously for five sec onds When the filter service life has elapsed the APP shows a filter mes sage via PUSH notification 12 1 MINI control unit filter message 12 1 1 Clearing the MINI control unit filter message 12 3 Filter message via PICHLER APP B At every filter maintenance always all 3 filters must be replaced MINI control unit filter message Flashing LED 12 4 Filter change B Only original repla...

Page 20: ...lter covers by pressing the latches positioned at the sides towards the inside 5 Remove the respective air filter by the flaps Note the direction of the air stream 6 Insert the new air filter and close the filter cover Note the direction of the air stream 7 Mount the design front again 8 Acknowledge the filter message by keeping the button pressed for 5 seconds 12 5 Procedure for the filter change...

Page 21: ...ually ensure that necessary human lifting and carrying forces are reasonable The packaging materials must be disposed of in accordance with local regulations wooden pallets or cartons must be recycled for instance Units that are no longer in working order must be dismantled by a specialised company and properly disposed of via suitable collection centres in accordance with the Waste Electrical and...

Page 22: ...14 1 Unit set up and dimensions 1 Supply air 2 Extract air 3 Outdoor air 100 mm 4 Exhaust air 100 mm 5 Enthalpy exchanger 6 Outdoor air fan 7 Exhaust air fan 8 Controller 9 Outdoor air flap 10 Exhaust air flap 11 Outdoor air filter ISO Coarse 70 12 Supply air filter ePM 55 13 Exhaust filter ISO Coarse 70 14 Cable inlets 17 Electric pre heating battery ...

Page 23: ...nto the ventilation unit The ventilation unit can be controlled optionally by using the pushbutton on the unit via Pichler APP or via the MINI control unit 9 Outdoor air flap Closes the outdoor air connection of the unit when the unit is switched off 10 Exhaust air flap Closes the exhaust air connection of the unit when the unit is switched off 11 Outdoor air filter ISO Coarse 70 Serves to pre fil...

Page 24: ...umidity ratio supply air 69 1 Specific input power SIP 0 28Wh m Classification of air filters in accordance with EN ISO 16890 ODA filter outdoor air pre filter ISO Coarse 70 SUP filter supply air fine filter ISO ePM1 55 ETA filter extract air ISO Coarse 70 Operating conditions Permissible operating temperature outdoor air with without preheating battery 15 C 5 C Condensate drainage not required 2 ...

Page 25: ...c tural Engineering III 57 1 51 3 7 20 1 At 70 of the max volume flow corresponds to ventilation level 2 2 When used as intended as living space ventilation unit no condensate will form 14 5 Sound data SINGLE ROOM APPLICATION Volume flow m3 h 25 42 60 Housing Sound pressure level at a distance of 1m LPA1m dB A 20 22 29 Sound power level LWA dB A 29 35 43 Outdoor air exhaust air Sound pressure leve...

Page 26: ...nally the ventilation unit LG 100 is available with an integrated electric PTC pre heating battery When the pre heating battery is active the cold outdoor air is pre heated via the electrical PTC heating element This operating mode provides a guaranteed balanced air flow volume between the supply air and extract air With a very low outdoor temperature when a defined exhaust temperature is underrun...

Page 27: ...0 Poor 5 0 Level 5 10 Bad CO 2 concentration in ppm Decreasing power of concentration headaches Disruptive Pleasant Closed window Mech domestic ventilation Fresh outdoor air 400 ppm Hours Ambient temperature in C Still comfortable Comfortable Uncomfortably dry Uncomfortably damp Based on Leusden und Freymark Graphics www komfortlüftunq at Relative humidity RH of the ambient air in Structural physi...

Page 28: ...the surface mounted housing you first have to remove the slide in module from the surface mounted housing and set it aside 16 1 Preparatory work 16 1 1 Removing the slide in module from the surface mounted housing 16 Mounting USER GENERAL SPECIALIST PERSONNEL Removing the slide in module from the surface mounted housing ...

Page 29: ...all The scope of supply includes a template to implement the core drilling of the outdoor air and exhaust air opening as well as the mounting point Mounting template for the LG 100 surface mounted housing 16 1 2 Removing the drilling template from the packaging board Dimensioning of the mounting template for the LG 100 surface mounted housing GENERAL USER SPECIALIST PERSONNEL ...

Page 30: ...screws by means of which the surface mounted housing is fitted as well as an indication of the position for the cable gland Afterwards drill the corresponding holes using a 142 mm size core drill and insert the screws for fitting the surface mounted housing 16 1 3 Structural measures for the installation of the surface mounted housing Placing the markings on the drilling template Drill core drilli...

Page 31: ...terwards drill the corresponding holes using a 142 mm size core drill and insert the dowels for fitting the surface mounted housing 16 2 Interior work 16 2 1 Assembling the outdoor air and exhaust air connections Insulate plastic pipes and shorten them flush with the wall Mount the conduit Foam using assembly foam Draw the cable B The cable must have a minimum excess length of 50 cm B The pipes mu...

Page 32: ...reserved The surface mounted housing is fitted on the screws and is then screwed on 16 2 2 Assembly of the surface mounted housing Fit the surface mounted housing Screw the surface mounted housing to the wall Screw the surface mounted housing tight USER GENERAL SPECIALIST PERSONNEL ...

Page 33: ...USER SPECIALIST PERSONNEL 16 3 Electrical connection In order to be able to implement the electrical connection work you must disassemble the control housing first B Electrical connection and work on electrical components may only be carried out by authorised electricians B The domestic ventilation unit LG 100 may be installed and operated appropriately at a fixed electrical installation only with...

Page 34: ...ling process has been carried out successfully fit the control housing again Optionally the ventilation unit can be controlled via the MINI control unit or via modbus RTU GLT connection A digital input is provided as External off contact NC or NO contact or at External ventilation level 3 contact as NO contact depending on the configuration The standard setting configured for the digital input is ...

Page 35: ...UNTED UNIT LG 100 AP PAGE 35 Changes reserved Completely mounted surface mounted unit Detailed view Afterwards the slide in module must be screwed tight to the surface mounted housing using the 4 screws supplied GENERAL USER SPECIALIST PERSONNEL ...

Page 36: ... we recommend inserting the outdoor air grille in clockwise direction in a manner slightly slanted to the right and the exhaust air grille in counter clockwise direction in a manner slightly slanted to the left in order to prevent an air short circuit The circumferential gap between the core drill holes and the outdoor air exhaust air ducts must be filled with assembly foam 16 4 Exterior work Exte...

Page 37: ...urpose the cover plate is pressed against the wall and slid into the retention points top down Installation of the design front in 2 steps B In order to ensure that the design front is tight it has to be fastened properly 16 4 1 2 INSTALLATION FROM THE INSIDE Open up the grill and draw it back Fix grille and place safety lanyard into the flush mounted housing Pass the plastic grille NW170 through ...

Page 38: ...acuum cleaner to remove dirt and dust Applying force or using compressed air for cleaning may damage the components and surfaces Never use aggressive or solvent containing cleaning agents The electrical components must not be exposed to moisture or wet conditions The safety information in Section 5 and in particular the item on electrical connections must be observed when performing any electrical...

Page 39: ...e The design front can now be remounted We recommend cleaning at least once a year depending on the level of soiling Handle the device surface with care when cleaning it Using excessive force during cleaning can cause damage to the surfaces Preferably use a cloth or a vacuum cleaner to remove dust Electrical components may not be exposed to moisture or wet conditions Be particularly careful not to...

Page 40: ...s reserved 17 5 Service table In order to document maintenance work this table must be completed after carrying out work on the unit System commissioned by Date No Maintenance work e g filter change Performed by Signature Date 1 2 3 4 5 6 7 8 9 10 USER GENERAL SPECIALIST PERSONNEL ...

Page 41: ...OPERATING AND INSTALLATION MANUAL SURFACE MOUNTED UNIT LG 100 AP PAGE 41 Changes reserved 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 GENERAL USER SPECIALIST PERSONNEL ...

Page 42: ...d ventilation Operation with a reduced volume flow for minimum ventilation of the building 25 m h 2 Standard ventilation Operation with the dimensioned volume flow for normal ventilation of the building 42 m h 3 Intensive ventilation Operation with an increased volume flow boost ventilation for short intensive ventilation of the building 60 m h 4 Automatic Operation with demand oriented control vi...

Page 43: ...t Z02 check voltage supply of MINI control unit Error Description Z01 No Internet connection possible Z02 Communication of combi sensor 1 Z03 Communication of combi sensor 2 Z04 Exhaust air fan blocked speed monitoring Z05 Outdoor air fan blocked speed monitoring Z06 Combi sensor 1 T1 outdoor air Z07 Combi sensor 1 volume flow outdoor air Z08 Combi sensor 1 relative humidity outdoor air Z09 Combi ...

Page 44: ...tdoor air fan blocked speed monitoring Z06 Combi sensor 1 T1 outdoor air Z07 Combi sensor 1 volume flow outdoor air Z08 Combi sensor 1 relative humidity outdoor air Z09 Combi sensor 1 VOC CO2 sensor outdoor air Z10 Combi sensor 2 T2 exhaust air Z11 Combi sensor 2 volume flow exhaust air Z12 Combi sensor 2 relative humidity exhaust air Z13 Combi sensor 2 VOC CO2 sensor exhaust air Z14 T3 extract ai...

Page 45: ...utdoor air and extract air 40LG0500006A SUP filter ISO ePM1 55 for the supply air 40LG0500007A 21 1 Control elements 21 2 Air filter B Only original spare parts may be used for repair and replacement work Dependable operation is ensured only if original spare parts are used 22 Changes reserved It is our constant endeavour to technically improve and optimise our products and we reserve the right to...

Page 46: ...___________ _______________________________________________________________________________________________________________________ _______________________________________________________________________________________________________________________ _______________________________________________________________________________________________________________________ ____________________________...

Page 47: ...________ _______________________________________________________________________________________________________________________ _______________________________________________________________________________________________________________________ _______________________________________________________________________________________________________________________ _______________________________...

Page 48: ...88 F 43 0 1 6880988 13 Sales offices in Slovenia and Serbia Sales partner in Europe Responsible for the content J PICHLER Gesellschaft m b H Photos Ferdinand Neumüller archive J PICHLER Gesellschaft m b H Text J PICHLER Gesellschaft m b H All rights reserved All photos Symbol photos Subject to change without notice Version 05 2021 EH Your partner installer Systematic ventilation ErP 2018 ErP 2018 ...

Reviews: