background image

Page iii

 

14-SLOT PXI CHASSIS 40-914

pickering

TECHNICAL SUPPORT

For Technical Support please contact Pickering Interfaces either by phone, fax, the website or via e-mail.

WARRANTY

All products manufactured by Pickering Interfaces are warranted against defective materials and workmanship  for a period of two 

years, excluding PXI chassis and LXI chassis, from the date of delivery to the original purchaser. Any product found to be defective 

within this period will, at the discretion of Pickering Interfaces be repaired or replaced.

Products serviced and repaired outside of the warranty period are warranted for ninety days.

Extended warranty and service are available. Please contact Pickering Interfaces by phone, fax, the website or via e-mail.

ENVIRONMENTAL POLICY

Pickering Interfaces operates under an environmental management system similar to ISO 14001.

Pickering  Interfaces  strives  to  fulfil  all  relevant  environmental  laws  and  regulations  and  reduce  wastes  and  releases  to  the 

environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and 

safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can 

be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.

Worldwide Technical Support and Product Information

http://www.pickeringtest.com

Pickering Interfaces Headquarters

Stephenson Road Clacton-on-Sea CO15 4NL United Kingdom

Tel: 

 

+44 (0)1255-687900

Fax: 

 

+44 (0)1255-425349

E-Mail:  

sales@pickeringtest.com

Observe the Electrical Hazard Warning detailed in Section 5.

Observe the Electrostatic Sensitive Device Caution detailed in Section 5.

Pickering Interfaces GmbH

Johann-Karg-Straße 30

D-85540

Haar-Salmdorf

Germany

Tel:  +49 89 125 953 160

Fax:  +49 89 125 953 189

E-Mail: desales@pickeringtest.com

Pickering Interfaces AB

Karl Nordströmsväg 31

432 53 

Varberg

Sweden

Tel:  +46 340-69 06 69

Fax:  +46 340-69 06 68

E-Mail: ndsales@pickeringtest.com

Pickering Interfaces Inc.

2900 Northwest Vine Street

Grants Pass

Oregon 97526

USA

Tel:  +1 541 471 0700

Fax:  +1 541 471 8828

E-Mail: ussales@pickeringtest.com

Pickering Interfaces s.r.o.

Smetanova 525

Trinec

739 61

Czech Republic

Tel:  +42 0558 339 168

Fax:  +42 0558 340 888

E-mail: cesales@pickeringtest.com

ˇ

Pickering Interfaces SARL

6 Rue De La Mare Blanche

77186 Noisiel

Marne Le Vallee

France

Tel +33 1 60 53 55 50

Fax +33 1 60 53 55 99

email frsales@pickeringtest.com

Pickering Interfaces Inc. 

(East Coast Regional Office)  

67 South Bedford Street, Suite 400W 

Burlington, Massachusetts 01803 

USA 

 

Tel:  +1 781 229 5882 

Fax:  +1 781 272 0558 

E-mail: ussales@pickeringtest.com

Summary of Contents for 40-914-101

Page 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos...

Page 2: ...Page 1 14 SLOT PXI CHASSIS 40 914 pickering Issue 5 4 January 2014 User Manual 14 Slot PXI Chassis Model No 40 914 pickeringtest com pickering...

Page 3: ...SERVED No part of this publication may be reproduced transmitted transcribed translated or stored in any form or by any means without the written permission of Pickering Interfaces Technical details c...

Page 4: ...n be produced distributed used and recycled or disposed of in a safe and environmentally friendly manner Worldwide Technical Support and Product Information http www pickeringtest com Pickering Interf...

Page 5: ...Page iv 14 SLOT PXI CHASSIS 40 914 pickering THIS PAGE INTENTIONALLY BLANK...

Page 6: ...Section 2 Technical Description 2 1 Backplane 2 1 Power Supply 2 3 Mechanical 2 4 Section 3 Installation 3 1 Getting Started 3 1 Installing The Chassis 3 3 Fan Speed Setting 3 4 Connecting The Saftey...

Page 7: ...Page vi 14 SLOT PXI CHASSIS 40 914 pickering THIS PAGE INTENTIONALLY BLANK...

Page 8: ...ntrol interface or embedded controller and up to 13 additional 3U peripheral modules The 40 914 chassis can be controlled from a PC using Pickering Interfaces PCI to PXI Control Interface 41 921 The 4...

Page 9: ...ces Connection Solutions catalog for a full list of connector cabling options including drawings photos and specifications This is available in either print or as a download Alternatively our web site...

Page 10: ...r expansion slots which are used for system controller modules that are wider than one slot As defined in the PXI specification these slots allow the controller to expand to the left to prevent the co...

Page 11: ...0 914 Star Triggers PCI Arbitration and Clock Signals Local Bus Local Bus Local Bus Local Bus System Controller Slot 1 Star Trigger PeripheralSlot 2 Peripheral Slot 4 Peripheral Slot 3 Peripheral Slot...

Page 12: ...ule Users may insert or remove a redundant power supply from the system without interrupting the system operation provided the backplane load can be supplied from one power supply module However for s...

Page 13: ...Page 2 4 SECTION 2 TECHNICAL DESCRIPTION pickering 14 SLOT PXI CHASSIS 40 914 MECHANICAL Figure 2 2 Mechanical Drawing For The 40 914 001 PXI Chassis...

Page 14: ...220V alternative Installation CD includes electronic manuals and chassis ini files Environment The 40 914 chassis uses industrial standard mechanical components and high performance connector technolo...

Page 15: ...duct the main power connector must be disconnected Dangerous voltages may be present under certain conditions use extreme caution Explosive Atmosphere Do not operate the chassis in conditions where fl...

Page 16: ...on both sides and through the rear Cooling Considerations The area above and below the chassis should be kept clear to ensure the inlet and exhaust air paths are not obstructed The user should allow a...

Page 17: ...its back with PXI slots facing upwards to gain access to the underside 3 Remove the 5 crosshead screws securing the fan tray to the underside of the chassis as shown in Figure 3 2 4 Carefully lower t...

Page 18: ...any modules being removed in a static protection bag 3 Ensure that the system is turned OFF but still connected to mains so that it remains grounded 4 Choose an appropriate slot in the rack 5 Remove t...

Page 19: ...its downward position 7 Hold the handle whilst slowly sliding the module into the module guides until the handle catches on the injector ejector rail refer to Figure 3 5 8 Raise the injector ejector...

Page 20: ...required ini file from the download location to your PC using the following link http www pickeringtest info downloads drivers Chassis 2 Copy the files to any convenient location on your PC for examp...

Page 21: ...Page 3 8 SECTION 3 INSTALLATION OPERATION pickering 14 SLOT PXI CHASSIS 40 914 THIS PAGE INTENTIONALLY BLANK...

Page 22: ...Therefore when maintaining the chassis we suggest you always do so in a static free environment Please follow the standard handling procedures for static sensitive devices and wear a grounded wrist st...

Page 23: ...soap residue Do not use abrasive cleaning agents on any part of the chassis Cleaning the Fan Filters Remove the fan filters from the bottom of the chassis Clean the filters by washing them in a mild s...

Page 24: ...ensitive Semiconductor Devices Certain semiconductor devices used in this equipment are liable to damage due to static voltage Observe the following precautions when handling these devices in their un...

Page 25: ...Page 5 2 14 SLOT PXI CHASSIS 40 914 pickering THIS PAGE INTENTIONALLY BLANK...

Page 26: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: