background image

Page 5.2

SECTION 5 - CONNECTOR INFORMATION

pickering

GENERAL PURPOSE REED RELAY MODULE  50-110/115-021/121

 

151 
152 
153 
154 
155 
156 
157 
158 
159 
160 
161 
162 
163 
164 
165 
166 
167 
168 
169 
170 
171 
172 
173 
174 
175 
176 
177 
178 
179 
180 
181 
182 
183 
184 
185 
186 
187 
188 
189 
190 
191 
192 
193 
194 
195 
196 
197 
198 
199 
200 

150 
149 
148 
147 
146 
145 
144 
143 
142 
141 
140 
139 
138 
137 
136 
135 
134 
133 
132 
131 
130 
129 
128 
127 
126 
125 
124 
123 
122 
121 
120 
119 
118 
117 
116 
115 
114 
113 
112 
111 
110 
109 
108 
107 
106 
105 
104 
103 
102 
101 

51 
52 
53 
54 
55 
56 
57 
58 
59 
60 
61 
62 
63 
64 
65 
66 
67 
68 
69 
70 
71 
72 
73 
74 
75 
76 
77 
78 
79 
80 
81 
82 
83 
84 
85 
86 
87 
88 
89 
90 
91 
92 
93 
94 
95 
96 
97 
98 
99 

100 

50 
49 
48 
47 
46 
45 
44 
43 
42 
41 
40 
39 
38 
37 
36 
35 
34 
33 
32 
31 
30 
29 
28 
27 
26 
25 
24 
23 
22 
21 
20 
19 
18 
17 
16 
15 
14 
13 
12 
11 
10 









A1 

C1 
A5 

C5 
A9 

C9 
A13 

C13 
A17 

C17 
A21 

C21 
A25 

C25 
A29 

C29 
A33 

C33 
A37 

C37 
A41 

C41 
A45 

C45 
A49 

C49 
A53 

C53 
A57 

C57 
A61 

C61 
 
Gnd 

A2 

C2 
A6 

C6 
A10 

C10 
A14 

C14 
A18 

C18 
A22 

C22 
A26 

C26 
A30 

C30 
A34 

C34 
A38 

C38 
A42 

C42 
A46 

C46 
A50 

C50 
A54 

C54 
A58 

C58 
A62 

C62 
 
Gnd 

A3 

C3 
A7 

C7 
A11 

C11 
A15 

C15 
A19 

C19 
A23 

C23 
A27 

C27 
A31 

C31 
A35 

C35 
A39 

C39 
A43 

C43 
A47 

C47 
A51 

C51 
A55 

C55 
A59 

C59 
A63 

C63 
 
Gnd 

A4 

C4 
A8 

C8 
A12 

C12 
A16 

C16 
A20 

C20 
A24 

C24 
A28 

C28 
A32 

C32 
A36 

C36 
A40 

C40 
A44 

C44 
A48 

C48 
A52 

C52 
A56 

C56 
A60 

C60 
A64 

C64 
 
Gnd 

151 
152 
153 
154 
155 
156 
157 
158 
159 
160 
161 
162 
163 
164 
165 
166 
167 
168 
169 
170 
171 
172 
173 
174 
175 
176 
177 
178 
179 
180 
181 
182 
183 
184 
185 
186 
187 
188 
189 
190 
191 
192 
193 
194 
195 
196 
197 
198 
199 
200 

150 
149 
148 
147 
146 
145 
144 
143 
142 
141 
140 
139 
138 
137 
136 
135 
134 
133 
132 
131 
130 
129 
128 
127 
126 
125 
124 
123 
122 
121 
120 
119 
118 
117 
116 
115 
114 
113 
112 
111 
110 
109 
108 
107 
106 
105 
104 
103 
102 
101 

51 
52 
53 
54 
55 
56 
57 
58 
59 
60 
61 
62 
63 
64 
65 
66 
67 
68 
69 
70 
71 
72 
73 
74 
75 
76 
77 
78 
79 
80 
81 
82 
83 
84 
85 
86 
87 
88 
89 
90 
91 
92 
93 
94 
95 
96 
97 
98 
99 

100 

50 
49 
48 
47 
46 
45 
44 
43 
42 
41 
40 
39 
38 
37 
36 
35 
34 
33 
32 
31 
30 
29 
28 
27 
26 
25 
24 
23 
22 
21 
20 
19 
18 
17 
16 
15 
14 
13 
12 
11 
10 









A1 

C1 
A5 

C5 
A9 

C9 
A13 

C13 
A17 

C17 
A21 

C21 
A25 

C25 
A29 

C29 

























Gnd 

A2 

C2 
A6 

C6 
A10 

C10 
A14 

C14 
A18 

C18 
A22 

C22 
A26 

C26 
A30 

C30 

























Gnd 

A3 

C3 
A7 

C7 
A11 

C11 
A15 

C15 
A19 

C19 
A23 

C23 
A27 

C27 
A31 

C31 

























Gnd 

A4 

C4 
A8 

C8 
A12 

C12 
A16 

C16 
A20 

C20 
A24 

C24 
A28 

C28 
A32 

C32 

























Gnd 

50-115-021 

50-115-121 

Figure 5.2 - General Purpose Reed Relay Module (50-115-021/121): Pin-Outs

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for PCI CONVENTIONAL 50-110-021

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...115 021 121 USER MANUAL GENERAL PURPOSE REED RELAY MODULE MODEL Nos 50 110 115 021 121 www pickeringtest com pickering ISO 9002 Reg No FM38792 Issue 4 0 April 2012 Artisan Technology Group Quality In...

Page 3: ...s publication may be reproduced transmitted transcribed translated or stored in any form or by any means without the written permission of Pickering Interfaces Technical details contained within this...

Page 4: ...ycled or disposed of in a safe and environmentally friendly manner Worldwide Technical Support and Product Information http www pickeringtest com Pickering Interfaces Headquarters Stephenson Road Clac...

Page 5: ...Page iv pickering GENERAL PURPOSE REED RELAY MODULE 50 110 115 021 121 THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 6: ...tion 3 1 Software Installation 3 2 Section 4 Programming Guide 4 1 Programming Options For Pickering PCI Cards 4 1 Module Architecture 4 2 Module Sub Units 4 3 Programming The Module 4 5 Section 5 Con...

Page 7: ...Page vi pickering GENERAL PURPOSE REED RELAY MODULE 50 110 115 021 121 THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 8: ...lays used in our PCI cards are manufactured by our sister company Pickering Electronics Pickering reed relays offer very high reliability over 108 operations with maximum switching performance especia...

Page 9: ...agrams for the 50 110 115 120 125 Reed Relay Card Operating Storage Conditions Operating Conditions Operating Temperature Humidity Altitude 0 C to 55 C Up to 90 non condensing 5000m Storage and Transp...

Page 10: ...relays depending on the module type The relays are energised via control signals from relay drivers U8 to U15 The relay driver is addressed by PCI bridge U1 to output the required signal Module confi...

Page 11: ...ION 2 TECHNICAL DESCRIPTION pickering GENERAL PURPOSE REED RELAY MODULE 50 110 115 021 121 THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www a...

Page 12: ...nded 2 Choose an appropriate free PCI slot in the host system 3 Remove the blanking plate for the chosen slot and retain the fixing screw 4 Carefully remove the card from its anti static bag and inser...

Page 13: ...ortcut on the Programs Pickering menu In the absence of LabVIEW the Runtime Engine is required to support the Pickering Test Panels application TESTING OPERATION After installation of the hardware sta...

Page 14: ...VI Interchangeable Virtual Instrument driver supports all Pickering Interfaces PXI switch cards that are consistent with the Iviswtch class model as are the great majority of cards in the System 40 45...

Page 15: ...Pickering card are organized into logical sub units each sub unit containing a set of objects of similar type and use These objects may be switches digital outputs digital inputs resistors power supp...

Page 16: ...2 A32 C32 B1 A1 C1 B2 A2 C2 A64 C64 A1 C1 A2 C2 A3 C3 50 110 121 64 x SPDT 50 115 021 32 x SPST 50 115 121 64 x SPST Sub Unit Bit Signal Path Relay Energised 50 110 021 50 115 021 Signal Path Relay En...

Page 17: ...31 A31 com31 A31 31 32 com32 A32 com32 A32 32 33 com33 A33 33 34 com34 A34 34 35 com35 A35 35 36 com36 A36 36 37 com37 A37 37 38 com38 A38 38 39 com39 A39 39 40 com40 A40 40 41 com41 A41 41 42 com42 A...

Page 18: ...iUInt32 values are needed to hold the entire pattern ViUInt32 data 2 data 0 1 Sets lowest bit to 1 chA1 to com1 pipx40_setChannelPattern vi sub_unit data data 0 0x20 Sets 6th bit chA6 to com6 All othe...

Page 19: ...CTION 4 PROGRAMMING GUIDE pickering GENERAL PURPOSE REED RELAY MODULE 50 110 115 021 121 THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www art...

Page 20: ...3 A27 B27 C27 A31 B31 C31 A35 B35 C35 A39 B39 C39 A43 B43 C43 A47 B47 C47 A51 B51 C51 A55 B55 C55 A59 B59 C59 A63 B63 C63 Gnd A4 B4 C4 A8 B8 C8 A12 B12 C12 A16 B16 C16 A20 B20 C20 A24 B24 C24 A28 B28...

Page 21: ...A39 C39 A43 C43 A47 C47 A51 C51 A55 C55 A59 C59 A63 C63 Gnd A4 C4 A8 C8 A12 C12 A16 C16 A20 C20 A24 C24 A28 C28 A32 C32 A36 C36 A40 C40 A44 C44 A48 C48 A52 C52 A56 C56 A60 C60 A64 C64 Gnd 151 152 153...

Page 22: ...configuration highlighting any potential configuration problems Specific details of all installed Pickering switch cards are included All the installed Pickering switch cards should be listed in the...

Page 23: ...TROUBLE SHOOTING pickering GENERAL PURPOSE REED RELAY MODULE 50 110 115 021 121 Page 6 2 THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www art...

Page 24: ...unction with the PCB layout diagram below to identify the position of faulty relays Figure 7 1 Modules 50 110 021 50 115 021 Component Layout RL1 U1 FX1 U14 U13 U12 U11 FX2 U10 U9 U8 C24 C23 C25 C26 C...

Page 25: ...9 RL20 RL21 RL22 RL23 RL24 RL25 RL26 RL27 RL28 RL29 RL30 RL31 RL32 RL33 RL34 RL35 RL36 RL37 RL38 RL39 RL40 RL41 RL42 RL43 RL44 RL45 RL46 RL47 RL48 RL49 RL51 RL53 RL55 RL57 RL59 RL61 RL63 RL50 RL52 RL5...

Page 26: ...ain semiconductor devices used in this equipment are liable to damage due to static voltage Observe the following precautions when handling these devices in their unterminated state or sub units conta...

Page 27: ...Page 8 2 pickering GENERAL PURPOSE REED RELAY MODULE 50 110 115 021 121 THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 28: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: