17
CHANGING OIL IN THE ANGLE GEAR
FLEXIBLE SHAFT EXTENSION
Flexible extension shafts are available for the Maxi Miller Power+ in lengths of 11 metres (36ft).
Do not
extend
the shaft by more than
one
extension and only use a Picote Solutions shaft extension and connector.
Before attaching or removing the shaft extension always make sure that the machine is fully turned off and un-
plugged.
1.
Machine as far as possible with the flexible shaft before fitting the extension.
2.
Remove the flexible shaft from the pipe.
3.
Push the extension down the pipe and then connect onto the existing flexible shaft using a shaft connector.
4.
You can then carry on machining.
Note: for vertical pipes connect the extension onto the existing flexible shaft before pushing the extension down
the pipe.
The oil should be changed after every 1000 hours of use or 12 months.
1.
Dismount the gear guard and the hand guard.
2.
Remove the shaft socket from the shaft.
3.
Loosen the bolts holding the angle gear.
4.
Pull the angle gear away from the motor following the axle of the motor.
5.
When the angle gear has been dismounted, loosen the oil screw (there is only one screw on the gearbox).
6.
Pour the old oil out and add the new oil.
7.
Reassemble the angle gear by repeating the previous steps in reverse order.
Appropriate oils to use:
Shell omala 100 or Agip blasia 100 or Tamoil ep 100
Amount of oil:
0,042 kg / 1.4815 oz
Window of change:
after every 3000 hours of use or 12 months
19
Picote Solutions Oy Ltd www.picotesolutions.com
If there is problem that you cannot resolve with this manual, please consult your Picote
Reseller or Picote Solutions.