background image

13

Thanks to the use of the most advanced active electronics, your new PIEGA P SUB 1 MKII is a cutting edge product in the field of 

subwoofers. Thanks to the variable „HP Filter Q“ it features the ability to simulate an unlimited range of sound characteristics. This 

enables you to adjust operation within the deep bass range to your individual audio requirements, as well as to those of the listening 

environment. 

PIEGA P SUB 1 MKII

Setting options for individual requirements...

Settings of the Sound Characteristics

VOLUME

>Use this knob to adjust the subwoofer volume 

Setting tip: Turn the subwoofer to maximum volume and then turn it 

down until it sounds too quiet for you

PHASE-SWITCH

>Use this switch to set the subwoofer to In Phase or Out of Phase. 

Depending on the type of loudspeaker, there will be a phase cancelling 

(little bass) or a phase correction (normal bass) 

>>Factory setting 0 

PHASE-SHIFT

 

>Use this knob to adjust the phase to your system

>>Factory setting 0 

SUBSONIC

>Use this selector switch to activate the SUBSONIC filter. This is used to 

filter out frequencies below 15 Hz and thus relieve the subwoofer of 

inaudible frequencies

>>Factory setting OFF

FILTER-Q

 

>Use this knob to set the filter quality in the range between 0.5 to 0.8 - 

Turning the knob clockwise will cause a dry, clean and very precise 

bass, turning the knob anti-clockwise will produce a warm and more 

mellow bass

CROSSOVER-FREQUENCY

 

>This knob is used for adjusting the crossover frequency between 

subwoofer and full-range speaker

>>Factory setting 80 – 100 Hz 

VOLUME

MIN.

MAX.

PHASE-SHIFT

180

0

PHASE-SWITCH

OFF

ON

SUBSONIC

FILTER-Q

60Hz

140Hz

40Hz

CROSSOVER

FREQUENCY

Summary of Contents for P SUB 1 MKII

Page 1: ...User Manual PIEGA P SUB 1 MKII Active Subwoofer Version 1 0...

Page 2: ...at is based on twenty years of R D and which in terms of its design represents the state of the art We are sure that you will gain much listening enjoyment from your new Piega loudspeaker products Alt...

Page 3: ...tics Setting options for individual requirements 14 Daily Use Care and maintenance 15 Warranty Conditions Service and warranty conditions Other configuration examples can be obtained from www piega ch...

Page 4: ...efully and pay special attention to the following precautions and warnings In your own interest we advise you to strictly observe the following procedure when installing your new PIEGA P SUB 1 MKII Wa...

Page 5: ...over 180 once more so that it is standing on the feet provided Check that the P SUB 1 MKII has not been damaged in transit Then place the P SUB 1 MKII in the required position Special care was taken...

Page 6: ...ects such as vases etc on the P SUB 1 MKII so as avoid the possibility of accidents The P SUB 1 MKII can be installed flexibly and easily Due to its relatively small size it can be integrated in any u...

Page 7: ...the following pages The LFE IN INPUT OUTPUT terminals for connecting to the AV receiver or the stereo amplifier require connection cables with cinch plugs The SPEAKER LEVEL INPUT terminals for connect...

Page 8: ...for information on the individual setup controls Connecting the System Benefit The most frequently used and ideal connection configuration for 5 1 surround mode The P SUB 1 MKII can be tuned for opti...

Page 9: ...configuration Ideal configuration for stereo mode CROSSOVER FREQUENCY 40Hz 140Hz LFE IN INPUT OUTPUT L R 60Hz PRE OUT L R Right Left 230V T3 15AL250V FOR 230V INPUT T5AL250V FOR 115V INPUT 115 230V 5...

Page 10: ...e System Benefit Preferred configuration in the high end range The loudspeakers are relieved in the deep bass range CROSSOVER FREQUENCY 40Hz 140Hz LFE IN INPUT OUTPUT L R L L R R SPEAKER LEVEL INPUTS...

Page 11: ...Connect the P SUB 1 MKII cable to the subwoofer terminal marked SPEAKER LEVEL INPUTS Connect the P SUB 1 MKII subwoofer cable to the amplifier terminal marked SPEAKER or similar Likewise connect up th...

Page 12: ...tion Connect the P SUB 1 MKII subwoofer cable to your stereo amplifier at the terminal marked SPEAKER or similar Connect the P SUB 1 MKII cable to the subwoofer terminal marked SPEAKER LEVEL INPUTS Li...

Page 13: ...er to In Phase or Out of Phase Depending on the type of loudspeaker there will be a phase cancelling little bass or a phase correction normal bass Factory setting 0 PHASE SHIFT Use this knob to adjust...

Page 14: ...maintenance Daily Use Procedure Clean the surface of the P SUB 1 MKII with a soft fluff free cloth If necessary the P SUB 1 MKII can be cleaned with a vacuum cleaner set to the lowest power setting Ne...

Page 15: ...horized to do this by Piega 6 If it is necessary for a device or part of it to be sent to Piega or an approved Piega workshop the sender is responsible for paying all transport costs in advance The or...

Page 16: ...SA Switzerland Design by Piega All rights reserved v1 0 040507 Subject to modification in particular technical modifications All specifications without guarantee PIEGA SA Bahnhofstrasse 29 CH 8810 Hor...

Reviews: