Intended Use 

The BioBalance is a Pulsed Electromagnetic Field (PEMF) Therapy device. It has been 
designed to generate a specific frequency signal for the applicator, which introduces a magnetic 
field into the body. It is intended to be used as a health and wellness device

 
 

Safety Instructions 

Please read the operating instructions carefully before using the BioBalance.  
 
To ensure safe use of the BioBalance: 

  Do not use the BioBalance if it is not working properly or if it has been damaged in any 

way. 

  The USB connector serves exclusively for software updates. Do not connect any device 

or cord other than a USB flash drive with software update to the USB connector of the 
BioBalance device. Do not try to charge an external appliance with the USB connector. 

  Only use the BioBalance with original accessories. 

  Keep the BioBalance away from water or other liquids. Do not drop the BioBalance, use 

it inappropriately, or expose it to extreme temperatures or high levels of humidity (not 
less than 10° C/50° F or more than 40° C/100° F or a relative humidity greater than 90%) 

  To avoid reciprocal interference, the BioBalance should not be operated in the vicinity of 

other electronic devices. If this is not possible, various unit functions should be closely 
monitored during operation so that proper use in accordance with the regulations is 
ensured. 

 

 
Attention / Contraindications 

Do not use the BioBalance when you have implanted electrical devices including pacemakers, 
cochlear implants, intrathecal pumps, etc. PEMFs have not been proven safe for pregnant 
women. People with overactive adrenal or thyroid glands should use PEMFs with caution, as 
glands can become over-stimulated and fatigued. Conditions with active bleeding should be 
controlled before PEMFs are applied. Users known to be especially vulnerable to cardiac 
rhythm disturbances should exercise caution when using high-intensity PEMFs near the heart. 

 

 

 

 

Summary of Contents for 462214

Page 1: ...Item no 462214 Operating Manual Item no 451600 0423...

Page 2: ...tery Operation 10 Operation on Mains Circuit 10 Operating the BioBalance 11 Switching the Device ON 11 Connecting the Applicators 11 Home Menu Navigation 11 Selecting a Program 12 Starting Pausing Sto...

Page 3: ...her liquids Do not drop the BioBalance use it inappropriately or expose it to extreme temperatures or high levels of humidity not less than 10 C 50 F or more than 40 C 100 F or a relative humidity gre...

Page 4: ...ormal household waste at the end of its life but hand it in at an official collection point for recycling By doing this you will help to protect the environment By labelling with CE mark the manufactu...

Page 5: ...peak 4 V Maximum magnetic field Mat S 10 Gauss Maximum magnetic field Mat L 5 Gauss Program parameters Therapy duration 10 min 12 h Basic frequency 300 400 600 800 and 1000 Hz Low frequency modulatio...

Page 6: ...Balance if it is not used with original accessories Mains Adapter and Cables Item no Description Quantity 462147 Mains Adapter SNT 15 2000US 1 462283 Small magnetic field applicator BioBalance Mat S 1...

Page 7: ...the display screen LED light for charging mode LED light for main circuit mode ON OFF Key Key to select menu and increase time setting Key to select menu and decrease time setting Key to increase inte...

Page 8: ...r is connected The unit will not run on battery power if the mains adapter is connected The unit cannot be charged while in operation Applicator sockets USB socket for software updates only Socket for...

Page 9: ...selects User Signal frequencies change based on the chosen program These two signals are layered together to create a unique stimulation pattern Basic signal The basic signal waveform is a modulated s...

Page 10: ...ode The battery level is indicated on the upper right side of the display with the symbol The battery needs to be recharged once the battery symbol doesn t have any bars Please note The device is auto...

Page 11: ...used for either of the two applicators The symbol appears in the top right corner of the display when an applicator is connected You may connect one or both applicators If both are connected both will...

Page 12: ...Confirm your selection by pressing the key Once you confirm the program with the key the screen will display program information Each program will default to a set time and intensity You can adjust th...

Page 13: ...the intensity use the keys on the right When a programs has ended you will hear three beeps Pausing a Program To pause the treatment press the key Press the key again to resume the treatment You will...

Page 14: ...ngs Menu Navigation Use the keys on the left until you select the Settings menu Confirm your selection by pressing the key Use the keys on the left until you select the desired option Confirm your sel...

Page 15: ...f the control unit Wait until the device has detected the flash drive then press the key to start the software update The files will automatically be copied and installed The device automatically rest...

Page 16: ...signal frequencies will spread out evenly over the course of the chosen treatment time Relax Basic Signal 300 600 800 1000 Hz User Signal Frequencies 13 12 11 10 9 8 7 6 5 4 Hz Default Treatment Time...

Page 17: ...e circumstance that batteries must not be disposed of in the household waste but professionally The chemical term of the hazardous substance is below the dustbin symbol You are obliged by law to retur...

Page 18: ...ture permeates the stimulator If moisture does permeate the stimulator a technical check must be carried out before re use Technical Check We recommend a technical check on the BioBalance every 24 mon...

Page 19: ...19 Manufacturer Pierenkemper GmbH Am Geiersberg 6 35630 Ehringshausen Deutschland www pierenkemper eu Operating manual REF 41600 0423 Version 20161020...

Reviews: