Summary of Contents for Pointoselect Digital

Page 1: ......

Page 2: ... Adjusting the stimulation settings 6 Adjusting the intensity 7 Adjusting the frequency 7 Adjusting the pulse width 7 Adjusting the volume of the signal tone 8 Switching the device off 8 Battery change 8 General Information Description of symbols 9 Technical data 9 Classification 10 Recalibration changes and repairs 10 Circuit diagrams spare parts lists and calibration instructions 10 Guarantee 11...

Page 3: ...s or high humidity only use at temperatures between 10 C and 40 C and at a relative humidity of less than 90 Never use the Pointoselect digital if it is malfunctioning or has been dama ged in any way After usage store the Pointoselect digital in its original packaging to pro tect it against damage and contamination Warning The Pointoselect digital should not be used close to other electronic devic...

Page 4: ...rtment see section Battery change The hand probe and the hand electrode must be connected to the respective output sockets of the Pointoselect digital Starting the device Start the Pointoselect digital by pressing the button The display screen shown left appears The most recently used settings are now loaded The battery symbol on in the upper left hand side of the display shows the state of charge...

Page 5: ...e and ear mode These op tions can only be selected in automatic measurement and manual measure ment operating modes Ear Ear Gold Only gold points are detected and displayed Ear Silver Only silver points are detected and displayed Body IMPORTANT In body mode only the inner sensor is analysed The gold silver detection ist not active and therefore not shown in the display Measurement Automatic In aut...

Page 6: ...on only gold points will be detected and displayed On Ear Silver modulation only silver points will be detected and displayed Attention On Body modulation only the inner sensor of the Pointoselect digital is operating No Gold Silver detection is completed or displayed Stimulation Stimulation can be carried out in every operating mode When pressing the button on the hand probe the probe stimulates ...

Page 7: ...buttons on the device console can be used either to select a user defined frequency or to select a frequency from the pre set frequency range illustration shows Nogier A Frequency range partly devided through 128 Nogier Bahr Frequences of meridian by Reininger Bahr A 2 3 Hz 1 4 6 Hz 1 6 44 Hz lung 7 5 21 Hz bladder B 4 6 Hz 2 9 4 Hz 2 4 32 Hz large intestine 8 4 77 Hz kidney C 9 1 Hz 3 18 7 Hz 3 3...

Page 8: ...ery change During operation the voltage of the battery is shown by the segments inside the battery symbol If the voltage falls below the critical value the Pointoselect digital switches off itself and or cannot be switched on again A new 9 V bat tery e g Type 6LR61 must be inserted into the device Switch off the device Open the battery compartment Remove the used battery from the battery compartme...

Page 9: ... appropriate collection point and not place it in the normal domestic unsorted waste stream This will benefit the environment for all Conform with Council Directive 93 42 EEC of 14 June 1993 concerning medical devices Technical data Acupuncture point finder with automatic and manual location functions and integrated stimulator Power supply 9 V block battery Dimensions approx 115 mm x 60 mm x 30 mm...

Page 10: ... changes and repairs The manufacturer is only responsible for the safety and performance of the Pointoselect digital if recalibration modifications and repairs are carried out by persons authorized by the manufacturer and if the Pointoselect digital is operated in accordance with the instruction manual Circuit diagrams spare parts lists and calibration instructions Upon request we will provide cir...

Page 11: ...the tip of the hand pro be Tissue and fat deposits can collect between the inner and outer sensors and cause faulty measurements To clean retract the outer sensor and wipe the inner sensor with a suitably treated piece of cotton wool Ensure that no moisture enters the device If moisture does enter the device then the device must undergo a technical inspection before being used again Combinations T...

Page 12: ......