TPP
INSTRUCTION MANUAL
Page 13
Date rev. 28/05/13
Rev. 07
6.
HOW TO CHANGE BLADES
6.1
TP-6000
Warning!
During blade removal, make sure the compressed air supply is shut off.
6.2
TP-6000-15 - TR-6000 - TR-6000-V - TS-6000
Warning!
During blade removal, make sure the compressed air supply is shut off.
- Use the supplied hexagonal key to
remove the M3 screw on the head and
take out the blade set. ( Fig.16)
- For reassemble the blade, insert the
blade set as indicated on the Fig. 16 and
fasten screw M3.
M3 SCREWS
Fig. 16
- Use the supplied hexagonal key & a
slotted screwdriver to remove the ring
nut and the M4 screw as indicated on
Fig. 17 and take out blades.
- For reassemble the blades follow below
phases:
1) Insert on screw M4 some thread
docking adhesive.
2) Insert blades on the head and fix M4
screw.
3) Hold blades closed by one hand and
fasten the M4 fasten until the blades are
blocked.
4) Fasten the ring nut.
5) Lightly unscrew the M4 screw, until
blades are autonomously open.
Fig. 17 – TR-6000
M4
SCREW
RING
NUT