background image

 

 

 

 
 
 
 
 

 

INSTALLATION AND OPERATION MANUAL 

TT2 NANOPOSITIONER 

 

 

PIEZOCONCEPT 

15 Rue du Bocage 

69008 LYON 

France 

Summary of Contents for TT2

Page 1: ...1 INSTALLATION AND OPERATION MANUAL TT2 NANOPOSITIONER PIEZOCONCEPT 15 Rue du Bocage 69008 LYON France ...

Page 2: ...om the PIEZOCONCEPT controller first set the command voltage to 0 0V then turn the AC power to the PIEZOCONCEPT controller off and finally wait one minute before disconnecting The TT2 has no user serviceable parts Only trained service personnel should perform service IMPORTANT All Technical Information recommendations and examples related to PIEZOCONCEPT Products made in this manual are based on i...

Page 3: ...cking the TT2 4 1 2 Handling the TT2 4 1 3 TT2 5 2 INSTALLATION 5 3 GROUND LOOPS 6 3 1 Prevention and identification of ground loops 6 4 OPERATING THE NANOPOSITIONING STAGE 6 4 1 Operating in closed loop mode 7 4 2 Care during operation 7 ...

Page 4: ...t damage To insure a long and useful life the following guidelines should be strictly followed Never insert anything into the EDM grooves The EDM grooves are the cuts that form the flexure hinges and separate the moving portion of the stage from the stage frame Severe damage may result if objects are inserted into these grooves Do not move the rotational stage by pushing on it with your hands or a...

Page 5: ...e surface to be mounted to is clean flat and free of burs Using a lint free cloth gently wipe the bottom or mounting surface of the TT2 to remove any particles or dust Always lift the TT2 by the Y axis bottom portion Never lift position attach or unattach the TT2 with the power applied IMPORTANT Check for ground loops Section 3 between the TT2 and the mounting surface To install use the M2 CHC hol...

Page 6: ...er ground to the mounting surface The stage is connected directly to the ground of the PIEZOCONCEPT s controller which in turn is connected to the ground of the AC power cord The PIEZOCONCEPT s controller enclosure is also at ground potential Attaching a grounding wire between any of the PIEZOCONCEPT s controller enclosure screws and the mounting surface may short circuit the ground loop In a few ...

Page 7: ...witch on The command voltage now controls the position of the nanopositioning stage Never disconnect the 9 Pin connectors with the power on Always set the command voltage to zero and turn the power off before disconnecting Allow 1 minute for the PZT actuators to discharge before disconnecting For more information see the PIEZOCONCEPT S CONTROLLER OPERATION MANUAL 4 2 Care during operation The TT2 ...

Reviews: