3.4.
5
Carefully measure the diagonal distance between the forward RH cone Figure 4 [10] and the aft LH cone
Figure 4 [8], and then the forward LH cone Figure 4 [7] and aft RH cone Figure 4 [9]. These dimensions must
be 2152 mm ±1,3 mm, refer to Fig. 4 .
4
Close Up
4.1 Remove the LH and RH Jig Assemblies from the aircraft.
4.2 Install the LH wing, refer to AMM 12-B-57-00-00-00A-720A-A or 12-B-57-00-00-00A-720B-A.
4.3 Install the RH wing, refer to AMM 12-B-57-00-00-00B-720A-A or 12-B-57-00-00-00B-720B-A.
4.4 Make sure that the work area is clean and clear of tools and other items.
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 27 MSN 545, 1001-1719, 1721-1942
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-05-50-07-00A-282A-A
UNCLASSIFIED
19.11.2019 Page 6