ELECTRIC CONNECTION
•
Check that the power voltage corresponds to that indicated on the
electrical data plate (Fig.4). The allowable field of tolerance must be
contained within ”+/- 5%.
•
The power cab!e plug must not be used as a switch, but must be inserted
into an electrical outlet controlled by a suitable differential switch
(magnetothermal.)
•
Power cable extensions should have wire sections proportional to length.
WIRE SECTION IS VALID FOR A MAXIMUM LENGTH OF 20M
HP
50 Hz
60 Hz
1
1.5 mm*
2.5 mm*
1.5
2.5 mm*
4 mm*
Insert the plug into the electrical outlet and start up the compressor by turning on the switch on the
control panel (fig.5). On the first start-up it is necessary to check that the rotation direction of the
fan flywheel is correct. The cooling air must egme out of the rear part of the sounddeadening
cabin. (Instrumentation side) only if the compressor is three-phase.
The electric system was inspected by the manufacturer at the time of the general inspection and
therefore guaranteed- as perfect and operating. Any damage caused by improper power
connections to the line automatically excludes the guarantee of electrical parts. To avoid improper
connections, consult a specialized technician.