8 |
P a g e
Hobby Oil Free Series: AIRBAG
User Guide
Operation
THERMAL PROTECTION
The motors of the compressor are fitted with an automatic
amperometric thermal switch with manual reset located outside
on the control panel of the housing (Fig.6)
When the thermal switch is tripped, wait a few minutes. Manually
reset the switch (Fig.8).
Should disconnection repeat, do not insist in resetting, but investigate the causes of start-up
failure of the electric motor and if necessary, contact the closest assistance centre.
CAUTION:
Before any intervention inside the sound-deadening cabin, make sure of the following:
•
The general line switch is in the "0" position.
•
The electrocompressor switch is disconnected in th "0" position.
•
The compressor is cut off from the compressed air system.
•
The compressor and the internal pneumatic circuit are unloaded from any
pressure.
PANEL REMOVAL
Unfasten the lock screws to remove the side panels
(Fig.9)