Whenever transporting an air compressor,
ensure all air is drained from the air receiver.
There should be NO residual air pressure in the
air receiver.
MAINTENANCE INSTRUCTIONS
⦁
Check that fuses or circuit breakers correspond to
motor rating. In case of 415-Volt units, check rotation
as indicated by arrow attached to unit. On 240-Volt
units, avoid using extension leads as they could
cause voltage drop and power loss to motor. If
extension is to be used, please follow the table
below.
TABLE 1.
KW
HP
VOLTS
RECOMMENDED WIRE
SIZE
1.65 2.25 240 HEAVY DUTY, 1.5MM SQUARE WIRE (MAX
LENGTH 20 M)
2.20 3.00 240 HEAVY DUTY, 1.5MM SQUARE WIRE
(MAX LENGTH 10 M)
⦁
Oil level should be at the centre of the oil sight glass
on the compressor pump. Do not overfill as this could
cause excessive oil being expelled from the crank
case breather.
⦁
Oil is to be replaced every 1000 working hours or on a
six (6) monthly basis. Recommended oil:
⦁
PILOT PCO-40G or equivalent (Stationary
models).
⦁
PILOT PCO-30G or equivalent (Portable
models).