                                         OPERATION 

 

        ELECTRIC UNITS 

 

Ensure ON/OFF switch is located on the pressure switch is in an 

OFF position (down), before inserting power plug into appropriate 

power point and applying power. 

 

Unit can then be switched on using the ON/OFF switch. The 

pressure switch will automatically start and stop the compressor 

when the air receiver drops below or reaches factory set cut-in 

and cut-out pressures respectively. 

 

 

ALWAYS SWITCH UNIT ON AND OFF VIA 

PRESSURE SWITCH TO ENSURE THE UNIT 

DOES NOT START AGAINST HIGH PRESSURE 

 

 

TO PREVENT DAMAGE TO UNIT OR PERSONS DO NOT 

ATTEMPT TO MODIFY, BYPASS OR REMOVE PRESSURE 

SWITCH OR SAFETY VALVE IN ANY WAY. 

“TM” OR “K” SERIES ARE DESIGNED TO OPERATE TO  

A MAXIMUM PRESSURE OF 10 BAR. 

 

 

The air receiver is equipped with a safety valve to release 

pressure in the event of a pressure switch cut-out failure. To 

prevent damage to the unit, do not attempt to modify, bypass or 

remove the pressure switch or safety valve in anyway. 

 

The motor features a manual overload protection (where fitted). 

In poor power conditions or motor over temperature conditions, 

this overload protector will cut power to the motor. To reset, 

wait for the motor to cool then press reset button. If problems 

persist, check for power ratings, faulty power or poor 

connections. 

 

 

 

 

Summary of Contents for TM325I

Page 1: ...p 1300 667 579 www pilotair com au INSTRUCTION AND PARTS LIST MODEL TM325I...

Page 2: ...ase take a moment to familiarise yourself with the information contained in the following sections of this guide before attempting to operate this unit LOCATION OF UNIT For optimum efficiency locate u...

Page 3: ...E TO PREVENT DAMAGE TO UNIT OR PERSONS DO NOT ATTEMPT TO MODIFY BYPASS OR REMOVE PRESSURE SWITCH OR SAFETY VALVE IN ANY WAY TM OR K SERIES ARE DESIGNED TO OPERATE TO A MAXIMUM PRESSURE OF 10 BAR The a...

Page 4: ...and to ensure no damage to the electric starter where fitted always open the EASY START valve until the unit is operating and then close for normal operation This valve is located on the motor pump pl...

Page 5: ...ver operate the unit without factory fitted belt guard belt drive models or pump shroud direct drive models Never operate the unit with damaged or exposed electrical wiring Do not alter adjust or remo...

Page 6: ...ll as this could cause excessive oil being expelled from the crank case breather Oil is to be replaced every 1000 working hours or on a six 6 monthly basis Recommended oil PILOT PCO 40G or equivalent...

Page 7: ...ll pressure from receiver For information regarding spare parts and or service please always quote model and serial number PLEASE KEEP THIS INFORMATION NEAR MACHINE SO IT CAN BE READ BY ANYONE ATTEMPT...

Page 8: ...an over temperature condition These reset buttons are located either on the pressure switch or the motor itself CHECK VALVE 240V 415V models only The Check Valve is located at the junction of the pump...

Page 9: ...p 1300 667 579 www pilotair com au TM325I PUMP...

Page 10: ...eries Units Classic K Series Units Petrol Industrial Series Units Three Phase Industrial Series Units will be free from defects due to defective factory workmanship or materials for a period of 3 year...

Page 11: ...purchase of its Products Pilot Air will not be liable for any losses or damages whether direct or indirect including property damage or personal injury consequential loss economic loss or loss of prof...

Page 12: ...or correction of operating faults under any warranty specified herein is to be made only after Pilot Air or its authorised representative have examined the unit to their satisfaction with their decis...

Page 13: ...nsumer may have under any warranty specified herein are in addition to other rights and remedies of a consumer under a law in relation to the goods to which these warranties relate Nothing in this doc...

Reviews: