p : 1300 667 579
www.pilotair.com.au
MAINTENANCE INSTRUCTIONS
Check that fuses or circuit breakers correspond to motor rating. In
case of 415-Volt units, check rotation as indicated by arrow
attached to unit. On 240-Volt units, avoid using extension leads as
they could cause voltage drop and power loss to motor. If extension
is to be used, please follow the table below.
TABLE 1.
KW
HP
VOLTS
RECOMMENDED WIRE SIZE
1.65 2.25 240 HEAVY DUTY, 1.5MM SQUARE WIRE (MAX LENGTH 20 M)
2.20 3.00 240 HEAVY DUTY, 1.5MM SQUARE WIRE (MAX LENGTH 10 M)
Oil level should be at the centre of the oil sight glass on the
compressor pump. Do not overfill as this could cause excessive oil
being expelled from the crank case breather.
Oil is to be replaced every 1000 working hours or on a six (6)
monthly basis. Recommended oil:
PILOT PCO-40G or equivalent (Stationary models).
PILOT PCO-30G or equivalent (Portable models).
Note: In humid and/or very low duty cycle environments,
condensate may collect in the sump. Under these conditions, it is a
requirement that the operator drain the residual water from the
sump on a regular basis and/or change the oil more frequently than
recommended above.
Whenever transporting an air compressor, ensure all air is drained
from the air receiver. There should be NO residual air pressure in
the air receiver.
Routine maintenance should be performed on at least a six (6)
monthly basis.
Condensation must be drained from air receiver at least weekly.