Operating instructions (translation from original IT)
Cod. OQ7_5ARG078EN
Emiss. 18-07-08 Rev. 5 - Agg. 20-04-16
36
17.2
ACCESS TO THE USER PROGRAMMING MENU
THE STORAGE OF ANY CHOSEN PARAMETER TAKES PLACE AFTER 60 SECONDS WITH THE
MACHINE TURNED ON.
To access the “User programming” menu and programme the electronic board, proceed as follows:
1.
press the programming key
2.
scroll through the screens by pressing the “PROG” key
3.
hold down the “PROG” key until the parameter blinks
4.
press the “+” or “-“ key to vary the parameter
5.
confirm the variation by holding down the “PROG” key
6.
scroll through the remaining parameters or quit programming by holding down the “PROG” key
The screens shown in sequence, with the possibility of changing the parameter, are listed below:
LCD
RANGE
DEFAULT
COMMENT
1
LANGUAGE
ENGLISH
LANGUAGE OF THE COUNTRY
OF DESTINATION
SET CHOSEN LANGUAGE
2
ROTARY TEST
STOP (*)
/
CHECK THE DIRECTION OF
ROTATION OF THE ELECTRIC
FAN
3
ROTARY TEST
START (*)
/
CHECK THE DIRECTION OF
ROTATION OF THE ELECTRIC
FAN
4
PRESSURE SET
7,5 bar
2 ÷ 15 bar
WORKING PRESSURE VALUE
SELECT SET PRESSURE
5
LOAD PRESS. GAP
1,5 bar
0,2 ÷ 3 bar
1 bar
SELECT THE PRESSURE RANGE
IN WHICH THE MACHINE
WORKS
6
HISTORY ALARM
/
ALARM HISTORY: STORES THE
LAST 16 ALARMS
7
CONDENSATE DRAIN
300 sec.
0 ÷ 999 s
300 sec
SELECT TIME INTERVAL
BETWEEN ONE CONDENSATE
DRAINAGE AND THE NEXT
8
CONDENSATE DRAIN
LOAD ONLY
LOAD ONLY
SELECT CONDENSATE
DRAINAGE METHOD
9
CONDENSATE DRAIN
ALWAYS
/
/
10
MACHINE STARTING
LOCAL
LOCAL
SELECT MACHINE START
METHOD
11
MACHINE STARTING
AUTO RESTART
/
SELECT MACHINE START
METHOD
12
MACHINE STARTING
REMOTE CONTROL
/
SELECT MACHINE START
METHOD
13
STAND-BY TIME
120 sec.
30 ÷ 600 s
120 sec
SELECT STAND-BY TIME
14
MACHINE STATUS
MOTOR STATUS
MOTOR STATUS
REAL MACHINE STATUS.
CHANGES THE CONTACT WITH
THE MOTOR TURNING
15
MACHINE STATUS
ALARMS INDICATOR
CHANGES THE CONTACT IN
THE PRESENCE OF AN ALARM
16
MACHINE STATUS
RUN INDICATOR
CHANGES THE CONTACT WITH
MACHINE ON OR IN STAND BY
17
INSERT CODE DATA
0
0
See Chap. 18
.
After 80 seconds the system quits programming automatically
(*) Screen shown only when the machine is stopped.
17.3
ACCESS TO THE SERVICE PROGRAMMING MENU (Password required)
Contact Power System
17.4
CHECKING AND SETTING THE SECOND TEMPERATURE PROBE (Password required)
Contact Power System