Function description
Operating Manual PSSu K F EI
1003303-EN-03
| 32
O-data type: FS_O_EI_CONTROL
I/O-data name
I/O data element
Meaning
BasicInterface
ActivateCascading:
BOOL
TRUE: Enable cascading output.
FALSE: Switch off cascading output.
BasicInterface
Alive: SAFEBOOL
Only used internally
BasicInterface
ErrorAcknowledgement:
BOOL
TRUE: Reset error
BasicInterface
Restart: SAFEBOOL
TRUE: Reset restart interlock
O-data type: FS_O_EI_REFPOS
I/O-data name
I/O data element
Meaning
SetSDIM
Set: SAFEBOOL
TRUE: Restart of monitoring functions SDIM
SetSDIM
Alive: SAFEBOOL
Only used internally
SetSOSM
Set: SAFEBOOL
TRUE: Restart of monitoring functions SOSM
SetSOSM
Alive: SAFEBOOL
Only used internally
O-data type: FS_O_EI_SSR_PARA
I/O-data name
I/O data element
Meaning
SSR_Parameter
Alive: SAFEBOOL
Only used internally
SSR_Parameter
MaxSpeed: SAFEWORD Maximum speed for safe speed range monitoring
(SSRM) and limit value for safe speed monitoring
1 (SSM1) in compressed form.
SSR_Parameter
MinSpeed: SAFEWORD
Minimum speed for safe speed range monitoring
(SSRM) in compressed form
4.9
Proximity switches
}
The following proximity switches can be used with a pnp or npn output:
– Inductive
– Capacitive
}
The proximity switches must be fitted so that at least one is always activated. In other
words, the proximity switches must be fitted so that the recorded signals always overlap.
}
The cable used to connect the proximity switches must be shielded (see connection dia-
grams in the chapter entitled "EMC-compliant wiring").
}
A DC voltage in the range of 0 - 30 V can be monitored via track S. It should be used to
monitor the supply voltage of the proximity switches.