PSEN ma2.1p-11/-31
Operating Manual PSEN ma2.1p-11/-31
22191-EN-02
15
Periodic test
}
Carry out a monthly function test on the safety switch and actuator.
}
Always test the function with series connections with the PSEN i1 interface and connec-
ted evaluation device.
}
Always test the function with single connections with a connected evaluation device.
}
The safety function may only be checked by qualified personnel.
Dimensions in mm
13
6,5
13
ø8
,5
36
22
6,8
Ø
4
,5
2
6
1
0
,6
M8
x1
ø8
,5
Ø
4
,5
36
22
2
6
Technical details
General
506406
506408
Approvals
CE, EAC (Eurasian), TÜV, cULus
Listed
CE, EAC (Eurasian), TÜV, cULus
Listed
Sensor's mode of operation
Magnetic
Magnetic
Coding level in accordance with EN
ISO 14119
Low
Low
Design in accordance with EN ISO
14119
4
4
Classification in accordance with
EN 60947-5-3
PDDB
PDDB
Electrical data
506406
506408
Supply voltage
Voltage
24 V
24 V
Kind
DC
DC
Voltage tolerance
-20 %/+20 %
-20 %/+20 %