PSEN cs6.2 M12/8
Operating Manual PSEN cs6.2 M12/8
1003425-EN-06
34
Technical details
General
Approvals
CE, EAC (Eurasian), ECOLAB, FCC, IC, TÜV, UL/
cUL
Sensor's mode of operation
Transponder
Coding level in accordance with EN ISO 14119
High
Design in accordance with EN ISO 14119
4
Classification in accordance with EN 60947-5-3
PDDB
Pilz coding type
uniquely coded
Transponder
Frequency band
122 kHz - 128 kHz
Max. transmitter output
15 mW
Electrical data
Supply voltage
Voltage
24 V
Kind
DC
Voltage tolerance
-20 %/+20 %
Output of external power supply (DC)
1 W
Max. switching frequency
3 Hz
Max. cable capacitance at the safety outputs
No-load, PNOZ with relay contacts
40 nF
PNOZmulti, PNOZelog, PSS
40 nF
Max. inrush current impulse
Current pulse, A1
0,5 A
No-load current
25 mA
Inputs
Number
2
Voltage at inputs
24 V DC
Input current range
1,6 - 3 mA
Semiconductor outputs
OSSD safety outputs
2
Signal outputs
1
Switching current per output
100 mA
Breaking capacity per output
2,4 W
Potential isolation from system voltage
No
Short circuit-proof
yes
Residual current at outputs
400 µA
Voltage drop at OSSDs
1 V
Conditional rated short circuit current
100 A
Lowest operating current
2 mA
Utilisation category in accordance with EN 60947-1
DC-12
Times
Test pulse duration, safety outputs
150 µs