Connection to control systems and evaluation devices
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
| 31
Use in PL d (Cat. 2) applications
}
1-channel operation for safety inputs S31 and S41 (solenoid operation) via safe outputs
}
2-channel processing of safety outputs
}
1-channel operation for interconnected safety inputs S31 and S41 (solenoid operation),
with 1 A
22
S31
S41
12
Lock/Unlock Request
A1
A2
24 V
0 V
S11 S21
Safety control system
Activation of guard locking
PSEN ml
actuator
PSEN ml
safety switch
6.3
Single connection
24 V 0 V
A1
A2
12
22
I2 (FS)
I1 (FS)
FS: Failsafe
A1
A2
S31
S41
Y32
O2 (FS)
O1 (FS)
I1
Y1
24 V
Actuator
Safety switch
Programmable safety system
Activation of guard locking