Function description
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
| 22
4.6
Auxiliary release
The auxiliary release enables guard locking to be opened from the access side to the
danger zone.
The safety switch has auxiliary releases on three sides.
INFORMATION
If guard locking is deactivated using the auxiliary release, there is a low sig-
nal at safety outputs 12 and 22. An error code will be issued (see under
) and the safety switch switches to a fault condition.
It is possible to open guard locking using the control system.
[1]
[2]
Legend
[1] Auxiliary release screw Torx T10
[2] Security screw Torx T10, sealed with varnish when delivered