PSEN opII3H Series
Operating Manual PSEN opII3H Series
1003503-EN-05
| 26
Installation and alignment
Please note:
}
The optical surfaces of the transmitter and receiver must be parallel to each other and ori-
ented opposite to each other.
}
The connection sides of the transmitter and receiver must be on the same side and at the
same height (see diagram).
[1]
[2]
[1]
[2]
[3]
[3]
[3]
[3]
True
False
Legend
[1] Transmitter
[2] Receiver
[3] Connection cable
}
The distance between the transmitter and receiver must be within the operating range of
the safety light curtain used (see
}
The installation surface must be at least as wide as the standard installation kit
}
The installation surface may have a flatness imperfection of no more than 1.5 mm.