background image

Order reference

Operating Manual PNOZ ml1p
21575-EN-06

26

9

Order reference

9.1

Product

Product type

Features

Order No.

PNOZ ml1p

Link Module

773 540

PNOZ ml1p 

coated version

Link module, coated version

773 545

9.2

Accessories

Terminator, jumper

Product type

Features

Order No.

PNOZmulti bus terminator Terminator

779 110

PNOZmulti bus terminator

coated

Terminator, coated version

779 112

KOP-XE

Jumper

774 639

KOP-XE coated

Jumper, coated version

774 640

Cable

Product type

Features

Order No.

PNOZ mli1p 5m screw

Cable, 5-pin, shielded, screw terminal, 5 m

773 890

PNOZ mli1p 10m screw

Cable, 5-pin, shielded, screw terminal, 10 m

773 891

PNOZ mli1p 50m screw

Cable, 5-pin, shielded, screw terminal, 50 m

773 892

PNOZ mli1p 5m spring

Cable, 5-pin, shielded, spring-loaded terminal, 5 m

773 893

PNOZ mli1p 10m spring

Cable, 5-pin, shielded, spring-loaded terminal, 10 m

773 894

PNOZ mli1p 50m spring

Cable, 5-pin, shielded, spring-loaded terminal, 50 m

773 895

PNOZ mli1p 1.5m spring Cable, 5-pin, shielded, spring-loaded terminal, 1.5 m

773 896

PNOZ mli1p 1.5m spring Cable, 5-pin, shielded, spring-loaded terminal, 1.5 m

773 897

SafetyNET p Cable

SafetyNET p cable, 1 - 500 m

380 000

Connection terminals

Product type

Features

Order No.

Set spring terminals

1 set of spring-loaded terminals

783 400

Set screw terminals

1 set of screw terminals

793 400

Summary of Contents for 773540

Page 1: ...PNOZ ml1p Operating Manual 21575 EN 06 Configurable safety systems PNOZmulti...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...on 4 Function Description 12 4 1 Integrated protection mechanisms 12 4 2 Functions 12 4 3 System reaction time 14 4 4 Block diagram 14 Section 5 Installation 15 5 1 General installation guidelines 15...

Page 4: ...Contents Operating Manual PNOZ ml1p 21575 EN 06 4 Section 9 Order reference 26 9 1 Product 26 9 2 Accessories 26...

Page 5: ...particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive...

Page 6: ...Introduction Operating Manual PNOZ ml1p 21575 EN 06 6 INFORMATION This gives advice on applications and provides information on special fea tures...

Page 7: ...lowing features Can be configured in the PNOZmulti Configurator Point to point connection via 4 core shielded and twisted pair cable 32 virtual inputs and 32 virtual outputs Status indicators Plug in...

Page 8: ...Overview Operating Manual PNOZ ml1p 21575 EN 06 8 2 3 Front view Shield Key 0 V 24 V Supply connections CA CA CB CB Connections for 2 expansion modules PNOZ ml1p Shield Connection for the cable shield...

Page 9: ...increased environmental requirements see Technical details 22 The following is deemed improper use in particular Any component technical or electrical modification to the product Use of the product ou...

Page 10: ...ipment devices systems plant and machinery in accordance with the general standards and guidelines for safety technology It is the company s responsibility only to employ personnel who Are familiar wi...

Page 11: ...re met This operating manual only describes the basic functions of the unit The expanded functions are described in the PNOZmulti Configurator s online help Only use these functions once you have read...

Page 12: ...switch the outputs on the base unit and expansion modules accordingly The LEDs on the base unit and expansion modules indicate the status of the configurable control system PNOZmulti The online help...

Page 13: ...ule a calculation must always be made in accordance with the above formulas Input delay and switch off delay are only included once in the reaction time The data transmission time between the link mod...

Page 14: ...s i0 i31 Virtual outputs o0 o31 4 3 System reaction time Calculation of the maximum reaction time between an input switching off and a linked out put in the system switching off is described in the do...

Page 15: ...rail in an upright position so that the earthing springs on the control system are pressed on to the mounting rail The ambient temperature of the PNOZmulti units in the control cabinet must not excee...

Page 16: ...on module on the left hand side Install the expansion module in the position in which it is configured in the PNOZmulti Configurator The position of the expansion modules is defined in the PNOZmulti C...

Page 17: ...cable length may be max 100 m The reduced cable length must be configured in the PNOZmulti Configurator Connect the inputs and outputs from two PNOZ ml1p with a 4 core shielded cable The cables must...

Page 18: ...o the system the project must be amended using the PNOZmulti Configurator Proceed as described in the operat ing instructions for the base unit NOTICE For the commissioning and after every program cha...

Page 19: ...ule switch off delay tCOND of the semiconductor output at O0 tSUM tON n tBUS tCOND tSUM 4 ms 1 35 ms 30 ms 69 ms Reaction time tSUM between base unit Base 1 and Base 3 Input delay tON at I3 und I6 dat...

Page 20: ...xample 1 After pressing S1 on Base 1 the semiconductor outputs switch after the following reaction times tSUM O0 on Base 1 69 ms O1 on Base 3 104 ms O0 on Base 4 139 ms O0 on Base 5 104 ms CHIP Card S...

Page 21: ...r operation The unit is not ready for operation FAULT Red External error Red Internal error No fault TR Yel low Connection to another PNOZ ml1p available No connection to another PNOZ ml1p 7 2 Fault d...

Page 22: ...ly interruption before de ener gisation 20 ms 20 ms Max data transmission time 35 ms 35 ms Environmental data 773540 773545 Ambient temperature In accordance with the standard EN 60068 2 14 EN 60068 2...

Page 23: ...22 35 x 7 5 EN 50022 Recess width 27 mm 27 mm Max cable length between two link modules 1 km 1 km Material Bottom PPO UL 94 V0 PPO UL 94 V0 Front ABS UL 94 V0 ABS UL 94 V0 Connection type Spring loade...

Page 24: ...24 Mechanical data 773540 773545 Stripping length with spring loaded terminals 9 mm 9 mm Dimensions Height 94 0 mm 94 0 mm Width 22 5 mm 22 5 mm Depth 121 0 mm 121 0 mm Weight 129 g 135 g Where stand...

Page 25: ...y EN 62061 SIL CL EN 62061 PFHD 1 h IEC 61511 SIL IEC 61511 PFD EN ISO 13849 1 2015 TM year 2 channel PL e Cat 4 SIL CL 3 8 82E 09 SIL 3 3 86E 05 20 All the units used within a safety function must be...

Page 26: ...PNOZ mli1p 10m screw Cable 5 pin shielded screw terminal 10 m 773 891 PNOZ mli1p 50m screw Cable 5 pin shielded screw terminal 50 m 773 892 PNOZ mli1p 5m spring Cable 5 pin shielded spring loaded term...

Page 27: ...T p ThE SPIrIT Of SAfETY are registered and protected trademarks of Pilz Gmbh Co KG in some countries We would point out that product features may vary from the details stated in this document dependi...

Reviews: