5.2.2.4
PNU 963: baud rate
This parameter defines the index of the baud rate that is used for PROFIBUS communication, and
can only be read. The baud rate is given out by the PROFIBUS-master.
The table below shows the indices with the according baud rates:
Index
0
1
2
3
4
5
6
7
8
9
Baud rate
12000
6000
3000
1500
500
187.5
93.75
45.45
19.2
9.6
5.2.2.5
PNU 965: PROFIDRIVE profile number
This parameter can be used to read out the number of the PROFIDRIVE profile. Profile Number 3,
Version 2 is used.
5.2.2.6
PNU 970: default parametersr
With this parameter you can reject all the parameters that are set and load the manufacturer’s
default values.
5.2.2.7
PNU 971: non-volatile saving of parameters
With this parameter you can save all the parameter settings to the EEPROM. To do this, the param-
eter must have the value PWE = 1 when the transfer takes place.
Page 24
User manual PROFIBUS DP PMCtendo DD4
5 Using the parameter channel