6.2.4
Digital torque (operating mode -2)
PZD 1
PZD 2
PZD 3
PZD 4
PZD 5
PZD 6
STW
I
setp
-
-
-
-
ZSW
I
act
incremental actual position
(32-bit, value range 24-bit)
manuf.-specific
status
-
Actual position (32-bit)
The range for the incremental position covers values from -2
31
to (2
31
-1).
Here one turn corresponds to 2
PRBASE
increments.
Manufacturer-specific status
In the process data, the upper 16 bits of the manufacturer-specific status register
(PNU 1002) are made available. The numbering starts again from 0.
The significance of the status register bits can be seen in the table in Chapter 5.2.3.3.
Digital current values (16-bit)
The digital current values are converted as follows:
[ ]
I A
digital current setpoint
I
setp
=
´
1640
6.2.5
Analog torque (operating mode -3) [in preparation]
PZD 1
PZD 2
PZD 3
PZD 4
PZD 5
PZD 6
-
-
-
-
-
-
6.2.6
Electronic gearing (operating mode -4)
PZD 1
PZD 2
PZD 3
PZD 4
PZD 5
PZD 6
STW
-
-
-
-
-
ZSW
n
act
actual position (32-bit)
manuf. status
-
Actual speed (16-bit)
The representation of the 16-bit actual speed value is normalized to the parameter for the
overspeed VOSPD
n
n
VOSPD
act
act
16
15
2
=
´
Actual position (32-bit)
The range for the actual position covers values from -2
31
to (2
31
-1).
Here one turn corresponds to 2
PRBASE
increments..
Manufacturer-specific status
In the process data, the upper 16 bits of the manufacturer-specific status register
(PNU 1002) are made available. The numbering starts again from 0.
The significance of the status register bits can be seen in the table in Chapter 5.2.3.3.
Page 42
User manual PROFIBUS DP PMCtendo DD4
6 Process data channel